<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445867027</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145501.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20111201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1140/epjd/e2011-20366-x</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1140/epjd/e2011-20366-x</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Stochastic homogenization of the laser intensity to improve the irradiation uniformity of capsules directly driven by thousands laser beams</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[M. Temporal, B. Canaud]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Illumination uniformity of a spherical capsule directly driven by laser beams has been assessed numerically. Laser facilities characterized by N D =12, 20, 24, 32, 48 and 60 directions of irradiation with associated a single laser beam or a bundle of N B laser beams have been considered. The laser beam intensity profile is assumed super-Gaussian and the calculations take into account beam imperfections as power imbalance and pointing errors. The optimum laser intensity profile, which minimizes the root-mean-square deviation of the capsule illumination, depends on the values of the beam imperfections. Assuming that the N B beams are statistically independents is found that they provide a stochastic homogenization of the laser intensity associated to the whole bundle, reducing the errors associated to the whole bundle by the factor \hbox{$1/N_{B}^{1{/}2}$} 1 / N B 1 / 2 , which in turn improves the illumination uniformity of the capsule. Moreover, it is found that the uniformity of the irradiation is almost the same for all facilities and only depends on the total number of laser beams N tot =N D ×N B .</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">EDP Sciences, SIF, Springer-Verlag Berlin Heidelberg, 2011</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Temporal</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Universidad Politécnica de Madrid, 28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Canaud</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">CEA, DAM, DIF, 91297, Arpajon, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">The European Physical Journal D</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">65/3(2011-12-01), 447-451</subfield>
   <subfield code="x">1434-6060</subfield>
   <subfield code="q">65:3&lt;447</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">65</subfield>
   <subfield code="o">10053</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1140/epjd/e2011-20366-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1140/epjd/e2011-20366-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Temporal</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Universidad Politécnica de Madrid, 28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Canaud</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">CEA, DAM, DIF, 91297, Arpajon, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">The European Physical Journal D</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">65/3(2011-12-01), 447-451</subfield>
   <subfield code="x">1434-6060</subfield>
   <subfield code="q">65:3&lt;447</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">65</subfield>
   <subfield code="o">10053</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
