<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445879653</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145538.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00604-010-0520-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00604-010-0520-0</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Compact optical instrument for simultaneous determination of oxygen and carbon dioxide</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Isabel Pérez de Vargas-Sansalvador, Antonio Martinez-Olmos, Alberto Palma, María Fernández-Ramos, Luis Capitán-Vallvey]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A multi-analyte platform based on a portable instrument is presented that enables oxygen and carbon dioxide to be determined in sample gases. The use of four sensing channels (two channels for each analyte to provide redundancy) warrants high system reliability. The sensing scheme in case of oxygen is based on the quenching of the phosphorescence of the platinum octaethylporphyrin complex. In case of carbon dioxide, a secondary inner-filter effect is exploited that is caused by a pH indicator whose color is reversibly changed. The sensing membranes were placed directly on the detectors and on the light sources so to make additional optical element dispensable, reduce system costs, avoid problems related to optical alignment, optimize the efficiency of data acquisition, and enable facile replacement of sensors. The resulting microcontroller-based system is immune against optical and electrical interferences, contains simple digital signal processing circuitry, and has low power consumption. The response of the system to the two gases was modeled, and calibration curves are corrected for effects of temperature. The instrument was characterized in terms of cross-sensitivity and dynamic response. It can determine oxygen and carbon dioxide in terms of volume percentage. Figure Gas sensing module for simultaneous determination of O2 and CO2</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2010</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Carbon dioxide</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Oxygen</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Optical gas sensor</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Phosphorescence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Portable instrumentation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pérez de Vargas-Sansalvador</subfield>
   <subfield code="D">Isabel</subfield>
   <subfield code="u">ECsens. Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Martinez-Olmos</subfield>
   <subfield code="D">Antonio</subfield>
   <subfield code="u">ECsens. Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Palma</subfield>
   <subfield code="D">Alberto</subfield>
   <subfield code="u">ECsens. Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fernández-Ramos</subfield>
   <subfield code="D">María</subfield>
   <subfield code="u">ECsens. Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Capitán-Vallvey</subfield>
   <subfield code="D">Luis</subfield>
   <subfield code="u">ECsens. Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">172/3-4(2011-03-01), 455-464</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">172:3-4&lt;455</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">172</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00604-010-0520-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00604-010-0520-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pérez de Vargas-Sansalvador</subfield>
   <subfield code="D">Isabel</subfield>
   <subfield code="u">ECsens. Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Martinez-Olmos</subfield>
   <subfield code="D">Antonio</subfield>
   <subfield code="u">ECsens. Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Palma</subfield>
   <subfield code="D">Alberto</subfield>
   <subfield code="u">ECsens. Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fernández-Ramos</subfield>
   <subfield code="D">María</subfield>
   <subfield code="u">ECsens. Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Capitán-Vallvey</subfield>
   <subfield code="D">Luis</subfield>
   <subfield code="u">ECsens. Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071, Granada, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">172/3-4(2011-03-01), 455-464</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">172:3-4&lt;455</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">172</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
