<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445879785</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145539.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00604-010-0459-1</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00604-010-0459-1</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Towards a monolithically integrated microsystem based on the green tape ceramics technology for spectrophotometric measurements. Determination of chromium (VI) in water</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Ricardo Alves-Segundo, Núria Ibañez-Garcia, Mireia Baeza, Mar Puyol, Julián Alonso-Chamarro]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A general procedure is presented for the fabrication of miniaturized continuous flow analytical microsystems based on photometric detection using the low temperature co-fired ceramics technology. Optical elements such as light emitting diodes and photodiodes (all in the size of a few hundred micrometers) are integrated by means of an off-chip approach. A simple procedure is demonstrated to integrate a glass window after the ceramic sintering in order to minimize the decrease in sensitivity due to the reduction of the optical path length when scaling down. A flow cell with a shape of a bubble has been used to increase the area of the light beam. The device is robust, affordable, and small-sized. It enables absorbance measurements to be performed in-situ or for continuous monitoring of environmental samples. Specifically, a microsystem is introduced for colorimetric determination of chromium (VI) ion in waters based on the diphenylcarbazide reagent as a model. Under the optimized conditions, a linear response is obtained for the concentration range from 0.1 to 20mgL−1, with a detection limit of 50μgL−1.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2010</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Low-temperature co-fired ceramics</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Microanalyzer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Photometric detection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Chromium (VI)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diphenylcarbazide</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Alves-Segundo</subfield>
   <subfield code="D">Ricardo</subfield>
   <subfield code="u">Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Centro Regional do Porto, Campus da Asprela, 4200-072, Porto, Portugal</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ibañez-Garcia</subfield>
   <subfield code="D">Núria</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Baeza</subfield>
   <subfield code="D">Mireia</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Puyol</subfield>
   <subfield code="D">Mar</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Alonso-Chamarro</subfield>
   <subfield code="D">Julián</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">172/1-2(2011-02-01), 225-232</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">172:1-2&lt;225</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">172</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00604-010-0459-1</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00604-010-0459-1</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Alves-Segundo</subfield>
   <subfield code="D">Ricardo</subfield>
   <subfield code="u">Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Centro Regional do Porto, Campus da Asprela, 4200-072, Porto, Portugal</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ibañez-Garcia</subfield>
   <subfield code="D">Núria</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Baeza</subfield>
   <subfield code="D">Mireia</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Puyol</subfield>
   <subfield code="D">Mar</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Alonso-Chamarro</subfield>
   <subfield code="D">Julián</subfield>
   <subfield code="u">Grup de Sensors i Biosensors, Departament de Química, Facultat de Ciències, Edifici C-Nord, Universitat Autónoma de Barcelona, 08193, Bellaterra (Cerdanyola del Vallès), Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">172/1-2(2011-02-01), 225-232</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">172:1-2&lt;225</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">172</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
