<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445880651</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145542.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110601xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00604-011-0567-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00604-011-0567-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Integrated micro/nano-fluidic system for mixing and preconcentration of dissolved proteins</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Khalid Anwar, Taeheon Han, Samuel Yu, Sun Kim]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">An integrated micro/nano-fluidic system is presented for protein analysis. It is comprised of an integrated micromixer (IMM) and a preconcentrator with a separation column. The passive and planar type of IMM is based on an unbalanced split and the cross collision of the fluidic streams. The IMM can be easily fabricated and integrated to the microfluidic system. The preconcentrator has nanochannels formed by the electrical breakdown of polydimethylsiloxane (PDMS) membrane by applying a high electrical shock, but without any nano-lithography. The integrated microdevice was used for sample preparation (mixing with tagging molecules) and subsequent concentration of proteins. Proteins were electrokinetically trapped near the junction of the micro/nanochannels. We show a conceptual design and a simple microfluidic system for purposes of mixing and preconcentration. Figure Mixing and preconcentration of dissolved proteins using an integrated micro/nano-fluidic system</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Micro/Nano-fluidic system</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Micromixer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Protein preconcentration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Electrokinetic trapping</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Anwar</subfield>
   <subfield code="D">Khalid</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Han</subfield>
   <subfield code="D">Taeheon</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Yu</subfield>
   <subfield code="D">Samuel</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kim</subfield>
   <subfield code="D">Sun</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">173/3-4(2011-06-01), 331-335</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">173:3-4&lt;331</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">173</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00604-011-0567-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00604-011-0567-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Anwar</subfield>
   <subfield code="D">Khalid</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Han</subfield>
   <subfield code="D">Taeheon</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Yu</subfield>
   <subfield code="D">Samuel</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kim</subfield>
   <subfield code="D">Sun</subfield>
   <subfield code="u">Department of Mechanical Engineering, Inha University, 402-751, Incheon, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">173/3-4(2011-06-01), 331-335</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">173:3-4&lt;331</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">173</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
