<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">44588147X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145544.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00604-011-0602-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00604-011-0602-7</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Electrochemical determination of paraquat using a DNA-modified carbon ionic liquid electrode</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Nannan Mai, Xiaoying Liu, Wanzhi Wei, Shenglian Luo, Wei Liu]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Deoxyribonucleic acid (DNA) was electrochemically deposited on a carbon ionic liquid electrode to give a biosensor with excellent redox activity towards paraquat as shown by cyclic voltammetry and differential pulse voltammetry. Experimental conditions were optimized with respect to sensing paraquat by varying the electrochemical parameters, solution pH, and accumulation time of DNA. Under the optimized conditions, a linear relation exists between the reduction peak current and the concentration of paraquat in the range from 5 × 10−8 mol L−1 to 7 × 10−5 mol L−1, with a detection limit of 3.6 × 10−9 mol L−1. The utility of the method is illustrated by successful analysis of paraquat in spiked real water samples. Figure The DNA was electrodeposited onto the CILE under +1.5V for 1200s. The electrochemical behaviors of paraquat on the modified electrode had been studied by cyclic voltammetry and differential pulse voltammetry. Five ml phosphate buffer (pH 7.0) solution was added into an electrochemical cell (10ml) and then paraquat was successfully added into the cell. The differential pulse voltammograms were recorded when swept from −0.8V to −0.3V. The peak currents at about −0.63V for paraquat were measured.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Carbon ionic liquid electrode</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">DNA</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Differential pulse voltammetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Electrochemistry deposition</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Paraquat</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mai</subfield>
   <subfield code="D">Nannan</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Liu</subfield>
   <subfield code="D">Xiaoying</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wei</subfield>
   <subfield code="D">Wanzhi</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Luo</subfield>
   <subfield code="D">Shenglian</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Liu</subfield>
   <subfield code="D">Wei</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">174/1-2(2011-07-01), 89-95</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">174:1-2&lt;89</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">174</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00604-011-0602-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00604-011-0602-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mai</subfield>
   <subfield code="D">Nannan</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Liu</subfield>
   <subfield code="D">Xiaoying</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wei</subfield>
   <subfield code="D">Wanzhi</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Luo</subfield>
   <subfield code="D">Shenglian</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Liu</subfield>
   <subfield code="D">Wei</subfield>
   <subfield code="u">State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Hunan, 410082, Changsha, People's Republic of China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Microchimica Acta</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">174/1-2(2011-07-01), 89-95</subfield>
   <subfield code="x">0026-3672</subfield>
   <subfield code="q">174:1-2&lt;89</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">174</subfield>
   <subfield code="o">604</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
