<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">46318257X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406164843.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070601xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10039-007-1239-y</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10039-007-1239-y</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Wolter</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Sekretariat Prof. Dr. Ch. Jürgens, BG-Unfallkrankenhaus Hamburg, Bergedorfer Straße 10, 21033, Hamburg, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">&quot;Intelligentes Implantat&quot;</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">Konzeption, gegenwärtige Realisation und zukünftiges Entwicklungspotenzial</subfield>
   <subfield code="c">[D. Wolter]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">&quot;Intelligent implant”</subfield>
   <subfield code="b">Conception, realization and future potential for development</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Der Begriff des &quot;intelligenten Implantats&quot; wurde 1991 bei der Darstellung einer neuen Osteosyntheseimplantatkonzeption vorgestellt. Es beinhaltet 3 wichtige Funktionen: Messen (Lastübertragung durch das stabilisierende Implantat), Informieren (Patient, Arzt) und Regeln (Implantatfestigkeit). Voraussetzung für die technische Umsetzung dieser Funktionen stellt die winkelstabile Verbindung zwischen Kraftträger und Schraube dar. In den vergangenen Jahren konnten leistungsfähige Mess- und Informationssysteme entwickelt und tierexperimentell getestet werden. Ihr bisheriger klinischer Einsatz ist erfolgreich. Die 3. Funktion, Regelung der Implantatfestigkeit, kann durch Veränderung der Implantatlänge erreicht werden. Entsprechende mechanisch oder elektrisch funktionierende Nagelimplantate stehen heute zur klinischen Anwendung zur Verfügung. Ihre Kombination mit einem System, das misst und entsprechend der Datenanalyse die Distraktion des Implantatsystems regelt, erscheint möglich. Größere Schwierigkeiten im Hinblick auf eine kontrollierbare Regelbarkeit der Implantatfunktion sind bei Plattensystemen zu erwarten.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">&quot;Intelligentes Implantat&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lastübertragung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Implantatfestigkeit</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Osteosynthese</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Telemetrie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">&quot;Intelligent implant”</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Load transfer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Implant stability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Osteosynthesis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Telemetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10039-007-1239-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10039-007-1239-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wolter</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Sekretariat Prof. Dr. Ch. Jürgens, BG-Unfallkrankenhaus Hamburg, Bergedorfer Straße 10, 21033, Hamburg, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
