<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463182650</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406164843.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070601xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10039-007-1238-z</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10039-007-1238-z</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Winkelstabile Osteosyntheseimplantate</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">Intraoperativ montierbares, telemetrisches Lastmesssystem</subfield>
   <subfield code="c">[F. Capanni, C. Jürgens]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">Angle-stable osteosynthesis implants</subfield>
   <subfield code="b">An intra-operative, mountable, telemetric load measurement system</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Es wurde ein intraoperativ montierbares, telemetrisches Lastmesssystem für multidirektional winkelstabile Osteosyntheseplatten entwickelt, bestehend aus einer internen Sensor- und Sende- sowie einer externen Leseeinheit. Die Sensoreinheit mit einliegendem Dehnungsmessstreifen (DMS) wird auf das Implantat geschraubt, die Sendeeinheit unter der Haut in einer Gewebetasche platziert. Sie enthält alle für die telemetrische Übertragung notwendigen elektronischen Komponenten. Über ihr wird ein externes Lesegerät, das die induktive Energieversorgung und Datenauslesung gewährleistet, angebracht. Alle internen Komponenten sind hermetisch gekapselt. Die Montage des Systems wurde an einem humanen Tibiapräparat überprüft. Anschließend wurde die untere Extremität oberhalb des Kniegelenks abgesetzt und kontrollierten mechanischen Untersuchungen unter statischer axialer Last unterzogen. Die nach Osteosynthese durchgeführte Montage des Lastmesssystems auf das Tibiaimplantat sowie die Einbettung der Sendeeinheit in eine Weichteiltasche verliefen problemlos, jedoch muss der Kabelanschluss im Bereich des Sensorgehäuses um 90° gedreht sein, um eine unnötige Weichteilspannung des umliegenden Gewebes zu vermeiden. Die mechanischen Untersuchungen zeigten eine enge Korrelation zwischen eingeleiteter Kraft und detektiertem Messsignal.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Intraoperative Montage</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lastmesssystem</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Telemetrie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Intelligentes Implantat</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Winkelstabile Platte</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Intra-operatively mountable</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Load measurement system</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Telemetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Intelligent implant</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Angle-stable plate</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Capanni</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Entwicklungslabor der Litos GmbH &amp; Co. KG, Bergedorfer Straße 10-12, 21033, Hamburg, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Jürgens</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">BG-Unfallkrankenhaus Hamburg, Hamburg, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10039-007-1238-z</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10039-007-1238-z</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Capanni</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Entwicklungslabor der Litos GmbH &amp; Co. KG, Bergedorfer Straße 10-12, 21033, Hamburg, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Jürgens</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">BG-Unfallkrankenhaus Hamburg, Hamburg, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>