<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463182669</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406164843.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070601xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10039-007-1234-3</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10039-007-1234-3</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Kniegelenkluxationen</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[O. Gonschorek, V. Bühren]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">Knee joint dislocations</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Kniegelenkluxationen sind seltene, aber schwer wiegende Verletzungen mit z.T. erheblichen Folgen. Begleitende Nerven- und Gefäßverletzungen sind nicht selten. Bei spontaner Reposition kann das Verletzungsausmaß initial unterschätzt werden. Die primäre Diagnostik muss die neurologische Untersuchung sowie die sichere Beurteilung des Gefäßstatus einschließen. Die Sicherung der Durchblutung des betroffenen Beins steht in der Akutphase im Vordergrund, Läsionen müssen notfallmäßig operativ versorgt werden. Bei drohendem Kompartment ist eine Faszienlogenspaltung erforderlich, die Instabilität wird temporär mittels Fixateur externe transfixiert. Bei Hochrasanztraumen sind Begleitverletzungen auszuschließen, bei sedierten und beatmeten Patienten z.B. mit Spiral-CT. Sind nur die Kreuzbänder betroffen, kann ein arthroskopisch gestützter Ersatz vorgenommen werden, Transplantate werden bevorzugt von der Gegenseite entnommen. Die im angloamerikanischen Sprachraum verwendeten Allografts haben sich in unserer Region noch nicht durchgesetzt. Bei ausgedehnten Kapselläsionen und Beteiligung der Kollateralbänder sind arthroskopische Techniken nicht indiziert, es sollte offen rekonstruiert und ggf. augmentiert werden; sekundär verbliebene Instabilitäten können gezielt dem Bandersatz zugeführt werden.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Kniegelenkluxation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Gefäßverletzung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">N.-peronaeus-Läsion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Transfixierung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Kapsel-Band-Rekonstruktion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Knee joint dislocation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Vascular disruption</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Peroneal nerve lesion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Transfixation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Ligamentous repair</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Gonschorek</subfield>
   <subfield code="D">O.</subfield>
   <subfield code="u">BG-Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418, Murnau, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Bühren</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">BG-Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418, Murnau, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10039-007-1234-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10039-007-1234-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Gonschorek</subfield>
   <subfield code="D">O.</subfield>
   <subfield code="u">BG-Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418, Murnau, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bühren</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">BG-Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418, Murnau, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
