<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463187806</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406164859.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10973-006-8078-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10973-006-8078-0</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Partialthermal reduction of ammonium paratungstate tetrahydrate</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">Evolved gas analysis (TG/DTA-MS) and solid state studies (XRD,FTIR)</subfield>
   <subfield code="c">[I. Szilágyi, J. Madarász, F. Hange, G. Pokol]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Thermal decomposition of ammonium paratungstate tetrahydrate, (NH4)10[H2W12O42]·4H2O has been followed by simultaneous TG/DTA and online evolved gas analysis (TG/DTA-MS) in flowing 10% H2/Ar directly up to 900°C. Solid intermediate products have been structurally evaluated by FTIR spectroscopy and powder X-ray diffraction (XRD). A previously unexplained exothermic heat effect has been detected at 700-750°C. On the basis of TG/DTA as well as H2O and NH3 evolution curves and XRD patterns, it has been assigned to the formation and crystallization heat of γ-tungsten-oxide (WO2.72/W18O49) from β-tungsten-oxide (WO2.9/W20O58) and residual ammonium tungsten bronze.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">FTIR spectroscopy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">mass spectrometry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">simultaneous TG/DTA</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">tungsten</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">X-ray diffraction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Szilágyi</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Madarász</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hange</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">GE Hungary ZRt., GE Consumer &amp; Industrial - Lighting, Váci út 77, 1340, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pokol</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Thermal Analysis and Calorimetry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">88/1(2007-04-01), 139-144</subfield>
   <subfield code="x">1388-6150</subfield>
   <subfield code="q">88:1&lt;139</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">88</subfield>
   <subfield code="o">10973</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10973-006-8078-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10973-006-8078-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Szilágyi</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Madarász</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hange</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">GE Hungary ZRt., GE Consumer &amp; Industrial - Lighting, Váci út 77, 1340, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pokol</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111, Budapest, Hungary</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Thermal Analysis and Calorimetry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">88/1(2007-04-01), 139-144</subfield>
   <subfield code="x">1388-6150</subfield>
   <subfield code="q">88:1&lt;139</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">88</subfield>
   <subfield code="o">10973</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
