<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463190173</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406164906.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20071101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10973-007-8387-y</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10973-007-8387-y</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Diphasic Domains Approach Method (DDAM)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">Binary and ternary phase diagrams plotting</subfield>
   <subfield code="c">[B. Cheynet, D. Barbier, S. Ricoud]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">If someone wants to plot an isobaric temperature-composition binary or an isobarothermal section of a ternary equilibria phase diagram he only needs to plot the limits of diphasic domains, it automatically gives the limits of the monophasic and triphasic fields. In such diagrams each diphasic domain is defined by two lines joining all the extremities of the tie-lines of the domain and limited by the first and the last one. These tie-lines are segments whose the extremities are in the plane of the diagram and can easily be determined by equilibria calculation codes. Then binary or ternary phase diagrams can be plotted only using conodes of the diphasic fields and the method used to determine the diphasic domains becomes the main point in binary and ternary phase diagrams plotting. A meshing of the surface of the diagram is certainly not the best way to obtain a rapid result. We propose an approach which consists to follow the curvature of the diphasic domains limits, the ‘Diphasic Domains Approach Method, DDAM', which allows a rapid and robust determination of binary and ternary diagrams.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media, LLC., 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Calphad</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">DDAM</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">diphasic domains</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">diphasic domains approach method</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">phase diagram</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">plot</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">thermodynamics</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cheynet</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">THERMODATA-INPG-CNRS, 6 rue du Tour de l'Eau, 38400, Saint Martin d'Hères, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Barbier</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">THERMODATA-INPG-CNRS, 6 rue du Tour de l'Eau, 38400, Saint Martin d'Hères, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ricoud</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">THERMODATA-INPG-CNRS, 6 rue du Tour de l'Eau, 38400, Saint Martin d'Hères, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Thermal Analysis and Calorimetry</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">90/2(2007-11-01), 333-336</subfield>
   <subfield code="x">1388-6150</subfield>
   <subfield code="q">90:2&lt;333</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">90</subfield>
   <subfield code="o">10973</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10973-007-8387-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10973-007-8387-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cheynet</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">THERMODATA-INPG-CNRS, 6 rue du Tour de l'Eau, 38400, Saint Martin d'Hères, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Barbier</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">THERMODATA-INPG-CNRS, 6 rue du Tour de l'Eau, 38400, Saint Martin d'Hères, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ricoud</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">THERMODATA-INPG-CNRS, 6 rue du Tour de l'Eau, 38400, Saint Martin d'Hères, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Thermal Analysis and Calorimetry</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">90/2(2007-11-01), 333-336</subfield>
   <subfield code="x">1388-6150</subfield>
   <subfield code="q">90:2&lt;333</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">90</subfield>
   <subfield code="o">10973</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
