<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463192354</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406164912.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10973-006-7838-1</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10973-006-7838-1</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Degroote</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">Technical University of Madrid, UPM, E.U.I.T. Agrícola, Dep. Ciencia y Tecnología Aplicadas, Ciudad Universitaria, 28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Controlparameters of flame spreading in a fuel container</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[E. Degroote]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The processes involved in flame spreading over liquid fuels are subject of this work. A heat and momentum transfer analysis has been undertaken for fuel temperatures below the flash-point that confirms (within this range of temperatures studied in this work) that flame spreading is assisted by a convection pattern ahead of the flame. This assistance mechanism, which is not observed for solid fuels, is the origin (for lower temperatures) of a pulsating behaviour of the flame. A first experimental determination of the characteristic horizontal length of this assistance zone will be given. The analysis of our data lead us to conclude that flame spreading can be reduced by simultaneously preventing the formation of the convection zone and reducing the fuel surface temperature.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">convection pattern</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">fire safety</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">flame spreading</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">liquid fuels</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Thermal Analysis and Calorimetry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">87/1(2007-01-01), 149-151</subfield>
   <subfield code="x">1388-6150</subfield>
   <subfield code="q">87:1&lt;149</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">87</subfield>
   <subfield code="o">10973</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10973-006-7838-1</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10973-006-7838-1</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Degroote</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">Technical University of Madrid, UPM, E.U.I.T. Agrícola, Dep. Ciencia y Tecnología Aplicadas, Ciudad Universitaria, 28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Thermal Analysis and Calorimetry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">87/1(2007-01-01), 149-151</subfield>
   <subfield code="x">1388-6150</subfield>
   <subfield code="q">87:1&lt;149</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">87</subfield>
   <subfield code="o">10973</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
