<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">463205227</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20170326183053.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20071101xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00103-007-0377-5</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00103-007-0377-5</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Gesundheitliche Bewertung dioxinähnlicher polychlorierter Biphenyle in der Innenraumluft</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">Mitteilungen der Ad-hoc-Arbeitsgruppe der Innenraumlufthygiene-Kommission des Umweltbundesamtes und der Obersten Landesgesundheitsbehörden</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Health evaluation of dioxin-like polychlorinated biphenyls in indoor air</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung : Zum Schutz der Gesundheit der Bevölkerung setzt die Ad-hoc-Arbeitsgruppe der Innenraumlufthygiene-Kommission des Umweltbundesamtes und der Obersten Landesgesundheitsbehörden Richtwerte für die Innenraumluft fest. Zur gesundheitlichen Bewertung polychlorierter Biphenyle (PCB) in der Raumluft folgt die Ad-hoc-Arbeitsgruppe der international eingeführten Vorgehensweise über Toxizitätsäquivalenzfaktoren und leitet einen Prüfwert von 5 pg PCB-TEQ pro Kubikmeter Innenraumluft ab. Da die Messung von PCBTEQ relativ aufwendig ist, wird ein Verfahren vorgestellt, mit dem die Summe der PCB-TEQ auf der Basis von PCB-Raumluftkonzentrationen, die mit Standardmethoden ermittelt wurden, abgeschätzt werden kann. Eine erste Abschätzung des TEQ-Wertes mithilfe des PCB-Summenwertes ist möglich, wenn dabei der Chlorierungsgrad des PCB-Gemisches berücksichtigt wird. So kann gezeigt werden, dass bei niedrig chlorierten PCB-Quellen (z. B. in Fugendichtungsmassen) die TEQ-Werte deutlich unter 5 pg/m3 liegen, wenn der Gesamt-PCB-Richtwert von 3 μg/m3 eingehalten wird. Bei hoch chlorierten PCBQuellen (z. B. in Deckenplatten) könnte bereits bei einem Gesamt-PCB-Wert über 1 μg/m3 ein TEQ-Wert von 5 pg/m3 überschritten sein. Angesichts der begrenzten Datenlage sind diese Abschätzungen mit erheblichen Unsicherheiten verbunden. Eine einfachere und gleichzeitig genauere Abschätzung des TEQ-Wertes gelingt unter Einbeziehung des dioxinähnlichen Leitkongeners PCB 118. Bei einer Unterschreitung von 0,01 μg PCB 118/m3 wird unabhängig von dem PCB-Quellentyp ein TEQWert von 5 pg TEQ/m3 in der Raumluft eingehalten.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2007</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Innenraumluft</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Dioxinähnliche PCB</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">PCB 118</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Richtwert</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fugenmasse</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Deckenplatte</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">indoor air</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">dioxin-like PCB</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">PCB 118</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">guideline value</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">sealant</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">ceiling board</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz</subfield>
   <subfield code="d">Steinkopff-Verlag</subfield>
   <subfield code="g">50/11(2007-11-01), 1455-1466</subfield>
   <subfield code="x">1436-9990</subfield>
   <subfield code="q">50:11&lt;1455</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">50</subfield>
   <subfield code="o">103</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00103-007-0377-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00103-007-0377-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz</subfield>
   <subfield code="d">Steinkopff-Verlag</subfield>
   <subfield code="g">50/11(2007-11-01), 1455-1466</subfield>
   <subfield code="x">1436-9990</subfield>
   <subfield code="q">50:11&lt;1455</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">50</subfield>
   <subfield code="o">103</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
