<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463206622</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405153128.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00202-006-0002-x</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00202-006-0002-x</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Performance of Three-Phase Motors after Disconnecting Damaged Coils</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Kai Brune, Hans Seinsch]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Despite the high quality of modern insulation systems, winding faults still represent the most frequent reason of outages of rotating electrical machines. When the damage is localized at one coil or a few adjacent coils, the user wishes to investigate the possibility of a provisional repair, in order to continue operation at least for a limited period of time. Up to now no reliable tools are available to predict the performance of a motor when one or more coils are disconnected from the winding train. This paper offers a new calculation method for all important performance characteristics (constant and pulsating torques, losses, current distribution, unbalanced magnetic pull) in case of winding asymmetries. The scheme covers all types of three-phase windings and all possible connection versions. The correctness of the computation results is thoroughly examined by many tests.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Winding faults</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Winding asymmetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Cut out coils</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Disconnection of winding branches</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Current distribution</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Harmonic torques</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pulsating torques</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Unbalanced magnetic pull</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Brune</subfield>
   <subfield code="D">Kai</subfield>
   <subfield code="u">A&amp;D LD TD2, Siemens AG, Vogelweiher Str. 1 - 15, 90441, Nürnberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Seinsch</subfield>
   <subfield code="D">Hans</subfield>
   <subfield code="u">Institut für Antriebssysteme und Leistungselektronik, Universität Hannover, Welfengarten 1, 30167, Hannover, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/4(2007-03-01), 271-283</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:4&lt;271</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00202-006-0002-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00202-006-0002-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Brune</subfield>
   <subfield code="D">Kai</subfield>
   <subfield code="u">A&amp;D LD TD2, Siemens AG, Vogelweiher Str. 1 - 15, 90441, Nürnberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Seinsch</subfield>
   <subfield code="D">Hans</subfield>
   <subfield code="u">Institut für Antriebssysteme und Leistungselektronik, Universität Hannover, Welfengarten 1, 30167, Hannover, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/4(2007-03-01), 271-283</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:4&lt;271</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>