<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463206649</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405153128.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00202-006-0008-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00202-006-0008-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Analysis of Temperature Distribution in Cast-resin Dry-type Transformers</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Ebrahim Rahimpour, Davood Azizian]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Non-flammable characteristic of dry-type cast- resin transformers make them suitable for residential and hospital usages. However, because of resin's property, thermal behavior of these transformers is undesirable, so it is important to analyze their thermal behavior. Temperature distribution of cast-resin transformers is mathematically modeled in this paper. The solution of the model was carried out successfully by finite difference method. In order to validate the model, the simulation results were compared with the experimental data measured from an 800 kVA transformer. Finally, the influences of some construction parameters and environmental conditions on temperature distribution of cast-resin transformers were discussed.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Thermal modeling</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Dry-type transformer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Cast-resin</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Finite difference</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Rahimpour</subfield>
   <subfield code="D">Ebrahim</subfield>
   <subfield code="u">Electrical Engineering Department, Faculty of Engineering, University of Zanjan, Daneshgah road (Tabriz road km 5), P. O. Box 45195-313, Zanjan, Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Azizian</subfield>
   <subfield code="D">Davood</subfield>
   <subfield code="u">Iran Transformer Research Institute (ITRI), Zanjan, Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/4(2007-03-01), 301-309</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:4&lt;301</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00202-006-0008-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00202-006-0008-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Rahimpour</subfield>
   <subfield code="D">Ebrahim</subfield>
   <subfield code="u">Electrical Engineering Department, Faculty of Engineering, University of Zanjan, Daneshgah road (Tabriz road km 5), P. O. Box 45195-313, Zanjan, Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Azizian</subfield>
   <subfield code="D">Davood</subfield>
   <subfield code="u">Iran Transformer Research Institute (ITRI), Zanjan, Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/4(2007-03-01), 301-309</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:4&lt;301</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
