<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463206878</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405153128.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00202-006-0014-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00202-006-0014-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Effective Two-terminal Numerical Algorithm for Overhead Lines Protection</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Zoran Radojević, Vladimir Terzija]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">In the paper an effective numerical algorithm for overhead lines protection, particularly fault location and adaptive autoreclosure, is presented. It is based on the two terminal line currents and voltages acquisition. For this purposes the synchronized sampling of all analogue input variables, i.e. the application of the Global Position System/Phasor Measurement Units, was assumed. The algorithm presented is derived in the spectral domain. By this the set of third harmonics variables and line parameters was also used. The prerequisite for successfully adaptive autoreclosure functionality realization was the suitable modelling of the electrical arc. Arc was considered as a source of higher harmonics, distorting by this other electrical variables. In the arc modelling, results of laboratory testing were used. Algorithm is tested for a typical network configuration, assuming by this that the line considered was short enough to neglect its capacitive nature. Based on the results obtained, it is very realistic that the algorithm presented could be implemented in praxis in modern Intelligent Electronic Devices (IEDs).</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fault location</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Electrical arc</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Protection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Transmission lines</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Spectral analysis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Synchronized phasors</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Radojević</subfield>
   <subfield code="D">Zoran</subfield>
   <subfield code="u">Department of Electrical Engineering, Konkuk University, Seoul, Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Terzija</subfield>
   <subfield code="D">Vladimir</subfield>
   <subfield code="u">Oberhausener Str. 33, 40472, Ratingen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/5(2007-05-01), 425-432</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:5&lt;425</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00202-006-0014-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00202-006-0014-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Radojević</subfield>
   <subfield code="D">Zoran</subfield>
   <subfield code="u">Department of Electrical Engineering, Konkuk University, Seoul, Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Terzija</subfield>
   <subfield code="D">Vladimir</subfield>
   <subfield code="u">Oberhausener Str. 33, 40472, Ratingen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/5(2007-05-01), 425-432</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:5&lt;425</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
