<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">463206894</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405153129.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170326e20070501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00202-006-0022-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00202-006-0022-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Strategies for Power Systems Expansion Planning in a Competitive Electrical Market</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Andreoni, A. Garcia-Agreda, T. Strada, J. Saraiva]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A new methodology is presented for decision making in long-term expansion planning. Power system expansion planning involves an intrinsic uncertainty on data and parameters, a fact often worsened by the new rules of deregulated electrical markets. The proposed procedure models both the uncertainty in load forecasting and the experience of the planning expert who uses fuzzy sets theory and fuzzy dynamic programming in the model algorithm to find an optimal expansion alternative.This procedure was tested in a realistic model system and the results obtained were arranged in an expansion planning ranking list according to their membership in the decision set.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Electrical competitive market</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fuzzy dynamic programming</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Growth planning</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Power system</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Andreoni</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Electrical Energy Institute of San Juan National University, Argentina. Av. Libertador San Martín (Oeste) 1109, 5400, San Juan, Argentina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Garcia-Agreda</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Duke Energy International, Houston, TX, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Strada</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Electrical Energy Institute of San Juan National University, Argentina. Av. Libertador San Martín (Oeste) 1109, 5400, San Juan, Argentina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Saraiva</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">INESC Porto, Porto, Portugal</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/5(2007-05-01), 433-441</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:5&lt;433</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00202-006-0022-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00202-006-0022-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Andreoni</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Electrical Energy Institute of San Juan National University, Argentina. Av. Libertador San Martín (Oeste) 1109, 5400, San Juan, Argentina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Garcia-Agreda</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Duke Energy International, Houston, TX, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Strada</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Electrical Energy Institute of San Juan National University, Argentina. Av. Libertador San Martín (Oeste) 1109, 5400, San Juan, Argentina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Saraiva</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">INESC Porto, Porto, Portugal</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Electrical Engineering</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">89/5(2007-05-01), 433-441</subfield>
   <subfield code="x">0948-7921</subfield>
   <subfield code="q">89:5&lt;433</subfield>
   <subfield code="1">2007</subfield>
   <subfield code="2">89</subfield>
   <subfield code="o">202</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
