<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">46572938X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323111737.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02039460</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02039460</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Nuclear decay studies of rare-earth fission-product nuclides using fast radiochemical separation techniques</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[J. Baker, D. Meikrantz, R. Gehrke, R. Greenwood]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A facility for the rapid radiochemical separation of individual rare-earth fission product nuclides from mixed fission products has been developed at the Idaho National Engineering Laboratory (INEL). This facility, called the INEL ESOL (elemental separation on-line) facility, includes an electroplated spontaneously fissioning252Cf source, a He jet transport system to deliver short half-life fission products from the252Cf hot cell to the radiochemistry laboratory, and a high pressure liquid chromatograph for the individual separation of rare-earth radioelemental fractions. The fission product collection and separation instrumentation is interfaced to a microprocessor that controls valves, motors and other devices and monitoring instrumentation. The data acquistion instrumentation can be controlled from a signal originating from the microprocessor or initiated manually. The results of some recent decay scheme studies on153Pm and154Pm are reported.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Akadémiai Kiadó, 1990</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Baker</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Meikrantz</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Gehrke</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Greenwood</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Radioanalytical and Nuclear Chemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">142/1(1990-09-01), 159-171</subfield>
   <subfield code="x">0236-5731</subfield>
   <subfield code="q">142:1&lt;159</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">142</subfield>
   <subfield code="o">10967</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02039460</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02039460</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Baker</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Meikrantz</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Gehrke</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Greenwood</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Idaho National Engineering Laboratory, EG&amp;G Idaho, Inc., P.O. Box 1625, 83415-7111, Idaho Falls, Idaho, (USA)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Radioanalytical and Nuclear Chemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">142/1(1990-09-01), 159-171</subfield>
   <subfield code="x">0236-5731</subfield>
   <subfield code="q">142:1&lt;159</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">142</subfield>
   <subfield code="o">10967</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
