<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465747205</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323111823.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00321970</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00321970</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">On the direct analysis of solid samples by graphite furnace atomic absorption spectrometry</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[D. Baxter, W. Frech]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Summary: We have studied some limitations of the solid sampling, cup-in-tube technique by comparison with a constant temperature two-step atomiser and found consistently lower vapour-phase temperatures and greater interferences in the former. With the former, higher vapour-phase temperatures and improved analytical results for lead and cadmium were found using Pd(NO3)2+Mg(NO3)2 instead of NH4H2PO4+Mg(NO3)2 as modifier. Investigations of methods to extend the useful calibration range revealed reduced vapour-phase temperatures in the presence of a convective gas flow during atomisation, and a greater potential for errors using non-resonance lines. With respect to the latter, the absorbance signal is much more sensitive to matrix induced changes in the temperature interval in which atoms are formed compared to resonance lines. Furthermore, at the lead 261.4 nm non-resonance line we observed overcompensation errors caused by cobalt when using a Zeeman-effect system, and undercorrection due to the AlCl(g) molecule with a continuum source background corrector.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 1990</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Baxter</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Frech</subfield>
   <subfield code="D">W.</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Fresenius' Journal of Analytical Chemistry</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">337/3(1990-01-01), 253-263</subfield>
   <subfield code="x">0937-0633</subfield>
   <subfield code="q">337:3&lt;253</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">337</subfield>
   <subfield code="o">216</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00321970</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00321970</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Baxter</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Frech</subfield>
   <subfield code="D">W.</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Fresenius' Journal of Analytical Chemistry</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">337/3(1990-01-01), 253-263</subfield>
   <subfield code="x">0937-0633</subfield>
   <subfield code="q">337:3&lt;253</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">337</subfield>
   <subfield code="o">216</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
