<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465748384</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323111826.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00323419</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00323419</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Generation and enrichment of AsCl3 for interference-free determination of trace levels of arsenic in steel by atomic absorption spectrometry</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Solomon Tesfalidet, Knut Irgum]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Summary: Arsenic was analysed after volatilization as arsenic trichloride, facilitated by evaporative concentration of hydrochloric acid. The generated gas was enriched in a cold trap and then revolatilized into a flame-in-tube atomizer for atomic spectrometric determination. No interference was observed at the 50 and 250 μg/l As levels when the potential interferents Ni, Co, Cu, and Fe were added at 5000 mg/l each, or as a mixture containing all ions at 1000 mg/l. Standardization against aqueous acidified As(III) solutions was therefore possible without the use of making agents. Analyses of five reference samples of various steel alloys showed good agreement with certified values. The detection limit for As was 3.9 μg/l in the dissolved sample, or 0.39 μg/g in the steel.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 1990</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Tesfalidet</subfield>
   <subfield code="D">Solomon</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Irgum</subfield>
   <subfield code="D">Knut</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Fresenius' Journal of Analytical Chemistry</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">338/6(1990-01-01), 741-744</subfield>
   <subfield code="x">0937-0633</subfield>
   <subfield code="q">338:6&lt;741</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">338</subfield>
   <subfield code="o">216</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00323419</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00323419</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Tesfalidet</subfield>
   <subfield code="D">Solomon</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Irgum</subfield>
   <subfield code="D">Knut</subfield>
   <subfield code="u">Department of Analytical Chemistry, University of Umeå, S-90187, Umeå, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Fresenius' Journal of Analytical Chemistry</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">338/6(1990-01-01), 741-744</subfield>
   <subfield code="x">0937-0633</subfield>
   <subfield code="q">338:6&lt;741</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">338</subfield>
   <subfield code="o">216</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>