<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465755321</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323111845.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00503857</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00503857</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Direct observation of critical fluctuations in a binary mixture</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[D. Beysens, P. Guenoun, F. Perrot]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Microscopic observations of concentration fluctuations in the range 1-500 μm have been performed in a number of binary fluids near their critical temperature (T c). A heterodyne technique has been used. The temperature range (T-T c = 1-25 mK) is such that the sizes of the fluctuations are larger than or equal to the correlation length, measured usually as the inverse half-width of the structure factor of the fluctuations. Image analysis has given some information about the free energy of the system determined from the intensity distribution function. Also, the shape of the fluctuations can be studied. These are self-similar over more than three decades, with a fractal dimension of D f = 2.8. This value is compared with a number of theoretical predictions.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">concentration fluctuations</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">critical phenomena</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">fractal dimensionality</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">liquid mixtures</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">percolation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Beysens</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Service de Physique du Solide et de Résonance Magnétique, CEA-CEN Saclay, 91191, Gif-sur-Yvette Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Guenoun</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Service de Physique du Solide et de Résonance Magnétique, CEA-CEN Saclay, 91191, Gif-sur-Yvette Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Perrot</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Service de Physique du Solide et de Résonance Magnétique, CEA-CEN Saclay, 91191, Gif-sur-Yvette Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal of Thermophysics</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">11/1(1990-01-01), 37-48</subfield>
   <subfield code="x">0195-928X</subfield>
   <subfield code="q">11:1&lt;37</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">11</subfield>
   <subfield code="o">10765</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00503857</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00503857</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Beysens</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Service de Physique du Solide et de Résonance Magnétique, CEA-CEN Saclay, 91191, Gif-sur-Yvette Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Guenoun</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Service de Physique du Solide et de Résonance Magnétique, CEA-CEN Saclay, 91191, Gif-sur-Yvette Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Perrot</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Service de Physique du Solide et de Résonance Magnétique, CEA-CEN Saclay, 91191, Gif-sur-Yvette Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal of Thermophysics</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">11/1(1990-01-01), 37-48</subfield>
   <subfield code="x">0195-928X</subfield>
   <subfield code="q">11:1&lt;37</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">11</subfield>
   <subfield code="o">10765</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
