<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465783481</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112001.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02442668</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02442668</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Spectral analysis of heart rate variability signal and respiration in diabetic subjects</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Bianchi, B. Bontempi, S. Cerutti, P. Gianoglio, G. Comi, M. Natali Sora]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The paper deals with methods of processing ECG and respiration signals which aim at detecting parameters whose values may be correlated to normal and diabetic subjects with or without cardiovascular autonomic neuropathy (CAN). Beatto-beat R-R duration values of the ECG and discrete series of respiration are obtained from original signals using a recognition algorithm. Power spectrum analysis (autospectra, cross-spectra and coherence via autoregressive modelling) is carried out on segments of about 200 consecutive cardiac cycles. Spectral parameters of the R-R variability signal are obtained as follows: total power, power of low-frequency (LF) and high-frequency (HF) components, power of the signal which is (or is not) coherent with respiration, in absolute or in percentage values. The experimental protocol considers 40 diabetic patients (21 of whom have diabetic neuropathy) and 14 normals in three different conditions: resting, standing and controlled respiration. The developed spectral parameters seem sensitive enough to differentiate between normal and pathological subjects. These parameters may constitute a quantitative means to be edded to the classical diabetic tests for the diagnosis of cardiovascular autonomic neuropathy.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">IFMBE, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Biological signal processing</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diabetic neuropathy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Heart rate variability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Respiration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Sympathetic and parasympathetic nervous systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Bianchi</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Bontempi</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cerutti</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Gianoglio</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Comi</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Cattedra di Neurologia, Università di Milano, IRCCS Ospedale S. Raffaele, via Olgettina 60, 20124, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Natali Sora</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Cattedra di Neurologia, Università di Milano, IRCCS Ospedale S. Raffaele, via Olgettina 60, 20124, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Medical and Biological Engineering and Computing</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">28/3(1990-05-01), 205-211</subfield>
   <subfield code="x">0140-0118</subfield>
   <subfield code="q">28:3&lt;205</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">11517</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02442668</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02442668</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bianchi</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bontempi</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cerutti</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Gianoglio</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Dipartimento di Elettronica, Politecnico di Milano, Cantro di Teoria del Sistemi del CNR, Piazza Leonardo da Vinci 32, 20133, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Comi</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Cattedra di Neurologia, Università di Milano, IRCCS Ospedale S. Raffaele, via Olgettina 60, 20124, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Natali Sora</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Cattedra di Neurologia, Università di Milano, IRCCS Ospedale S. Raffaele, via Olgettina 60, 20124, Milano, Italy</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Medical and Biological Engineering and Computing</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">28/3(1990-05-01), 205-211</subfield>
   <subfield code="x">0140-0118</subfield>
   <subfield code="q">28:3&lt;205</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">11517</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
