<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465783562</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112002.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02446152</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02446152</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Multimicroprocessor system for online monitoring in a CCU</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[S. Barro, R. Ruiz, J. Mira]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A real-time monitoring system for physiological signals, developed for patients in coronary care units (CCUs), is described. This system monitors the signals that have the greatest clinical value in a CCU environment (ECG and cardiovascular pressures), taking charge of detecting dangerous situations and of extracting information significant to the correct monitoring of the patient. The information it extracts, mainly from the ECG, is presented to the user in an ergonomic way using written reports and graphs which collect and compile the information, facilitating its interpretation. Some utilities have been developed to allow the user to modify certain monitoring conditions as well as to correct results derived from them, thereby improving the reliability of the monitoring process. The system uses a multimicroprocessor architecture (imposed by the need to perform a large number of tasks in real time) with a block based on the VME bus, charged with acquiring and processing the monitored signals, and an IBM-compatible PC/XT which is used as a system user interface and a massive storage device in which the information resulting from the monitoring of signals is stored.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">IFMBE, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Arrhythmia detection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">CCU patient monitoring</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Multimicroprocessor applications</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Physiological signal processing</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Barro</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Departmento de Electrónica, Facultad de Fisica, Universidad de Santiago de Compostela, Santiago de Compostela, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ruiz</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Departmento de Electrónica, Facultad de Fisica, Universidad de Santiago de Compostela, Santiago de Compostela, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mira</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Departmento de Electrónica, Facultad de Fisica, Universidad de Santiago de Compostela, Santiago de Compostela, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Medical and Biological Engineering and Computing</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">28/4(1990-07-01), 339-349</subfield>
   <subfield code="x">0140-0118</subfield>
   <subfield code="q">28:4&lt;339</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">11517</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02446152</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02446152</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Barro</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Departmento de Electrónica, Facultad de Fisica, Universidad de Santiago de Compostela, Santiago de Compostela, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ruiz</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Departmento de Electrónica, Facultad de Fisica, Universidad de Santiago de Compostela, Santiago de Compostela, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mira</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Departmento de Electrónica, Facultad de Fisica, Universidad de Santiago de Compostela, Santiago de Compostela, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Medical and Biological Engineering and Computing</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">28/4(1990-07-01), 339-349</subfield>
   <subfield code="x">0140-0118</subfield>
   <subfield code="q">28:4&lt;339</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">11517</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
