<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465813402</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112121.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02915526</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02915526</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Marburger concept for computer-aided acquisition, processing and documentation of patient data in the intensive care unit</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[W. Höltermann, M. Knoch, H. Pfeiffer, E. Müller, H. Lennartz]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The authors report on their experience with the computer-aided acquisition, processing and documentation of patient data in an intensive care unit. The goal of an effective data and information collection system in the intensive care unit is to make therapy, and the patients respond to it, recognizable and understandable through the clear and complete representation of the patients conditions. The focal point of the data documentation is the medical record. In the implementation of a computer-aided data documentation and processing system the application of one central PC is unpractical. Each bed will be equipped with its own PC, and all the individual PCs will be connected to one central PC, which functions as server, and to connected to another PC in the doctors room. The data will be managed in a powerfull database-management-system and be stored on an optical-disk. The development of an effective man/machine interface is especially important. In addition we can promote the user acceptance in other ways, so as to ensure a concret benefit for each user group.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Kluwer Academic Publishers, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">ICU</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">data documentation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">computer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">database</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">user-acceptance</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Höltermann</subfield>
   <subfield code="D">W.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Knoch</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pfeiffer</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Müller</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lennartz</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International journal of clinical monitoring and computing</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">7/1(1990-03-01), 7-13</subfield>
   <subfield code="x">0167-9945</subfield>
   <subfield code="q">7:1&lt;7</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">7</subfield>
   <subfield code="o">12521</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02915526</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02915526</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Höltermann</subfield>
   <subfield code="D">W.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Knoch</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pfeiffer</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Müller</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lennartz</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">Department of Anaesthesiology and Intensive Care Medicine, Phillips-University Hospital, Baldingerstr., D-3550, Marburg, West Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International journal of clinical monitoring and computing</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">7/1(1990-03-01), 7-13</subfield>
   <subfield code="x">0167-9945</subfield>
   <subfield code="q">7:1&lt;7</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">7</subfield>
   <subfield code="o">12521</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
