<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465813917</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112122.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19901101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF01329297</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF01329297</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Dealy</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Department of Chemical Engineering, McGill University, 3480 University Street, H3A 2A7, Montreal, Quebec, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Challenges in process rheometry</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[J. Dealy]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Process rheometers are useful as process sensors for on-line quality control as well as for process control. Unlike passive sensors for equilibrium properties, such as temperature and pressure, a rheometer must subject the material of interest to a controlled deformation while monitoring the resulting stress. To accomplish this in a compact, robust device suitable for use in a manufacturing environment is not straightforward. Problems that arise in processing applications include the need for frequent sample renewal without interference from the measurement or the process itself and the fact that the process stream is usually under pressure. Considerable ingenuity has been applied to developing rheometers to meet these requirements. However, there remain many potential applications for which presently available units are not suitable. In particular, special problems arise when a very fast response is required, when the fluid being processed is non-Newtonian or has a very high viscosity, and when it is a multiphase system, as for example in the case of mineral slurries. In addition, in food processing and fermentation applications, all the exposed surfaces of the rheometer must be sterilizable. Possible solutions to these problems are described.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Steinkopff, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">R heometers</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">o n-line</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">i n-line</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">n on-Newtonian fluids</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">s uspensions</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Rheologica Acta</subfield>
   <subfield code="d">Steinkopff-Verlag</subfield>
   <subfield code="g">29/6(1990-11-01), 519-522</subfield>
   <subfield code="x">0035-4511</subfield>
   <subfield code="q">29:6&lt;519</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">397</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF01329297</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF01329297</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dealy</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Department of Chemical Engineering, McGill University, 3480 University Street, H3A 2A7, Montreal, Quebec, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Rheologica Acta</subfield>
   <subfield code="d">Steinkopff-Verlag</subfield>
   <subfield code="g">29/6(1990-11-01), 519-522</subfield>
   <subfield code="x">0035-4511</subfield>
   <subfield code="q">29:6&lt;519</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">397</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
