<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465814077</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112122.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900501xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF01331360</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF01331360</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Braun</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Deutsches Kunststoff-Institut, Schloßgartenstraße 6, 6100, Darmstadt, FRG</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Einsatz von DMS- und Piezomeßtechnik zur direkten Schubspannungsermittlung in der Kapillarrheometrie</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[P. Braun]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Der Stand der Kapillarheometrie mit den Vor- und Nachteilen der einzelnen Systeme und Meßverfahren wird dargestellt. Ausgehend von diesem Stand werden zwei alternative Meßverfahren, nämlich Piezo-Einzelkraftund DMS-Meßverfahren, zur direkten Schubspannungsermittlung besprochen und eine nach diesem Prinzip konzipierte Versuchsdüse vorgestellt. Die mit dieser Düse erhaltenen Meßergebnisse zeigen im Vergleich zu konventionell, d. h. unter Anwendung des Bagley-Verfahrens, ermittelten Fließkurven im Falle der Einzelkraftmessung gute Übereinstimmung. Das Problem der Einlaufdruckkorrektur ist bei diesem Konzept von vornherein nicht vorhanden, und der ununterbrochene Fließkanal erlaubt, bei entsprechender Erweiterung auf zwei Kraftaufnehmer, einen unproblematischen Einsatz im On-line- oder sogar im In-line-Betrieb in der Polymerverarbeitung.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Steinkopff, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Rheometry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">c apillary rheometry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">piezo- f orce transducer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">o n-line rheometry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Rheologica Acta</subfield>
   <subfield code="d">Steinkopff-Verlag</subfield>
   <subfield code="g">29/3(1990-05-01), 243-251</subfield>
   <subfield code="x">0035-4511</subfield>
   <subfield code="q">29:3&lt;243</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">397</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF01331360</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF01331360</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Braun</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Deutsches Kunststoff-Institut, Schloßgartenstraße 6, 6100, Darmstadt, FRG</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Rheologica Acta</subfield>
   <subfield code="d">Steinkopff-Verlag</subfield>
   <subfield code="g">29/3(1990-05-01), 243-251</subfield>
   <subfield code="x">0035-4511</subfield>
   <subfield code="q">29:3&lt;243</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">397</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="986" ind1=" " ind2=" ">
   <subfield code="a">SWISSBIB</subfield>
   <subfield code="b">465814077</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
