<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465825591</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112148.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02832184</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02832184</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="2">
   <subfield code="a">A low-cost, high-fidelity fm wireless precordial radiostethoscope for continuous monitoring of heart and breath sounds</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Alan Mizutani, George Ozaki, Jonathan Benumof]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">We constructed and tested an inexpensive (less than S50) FM wireless, acoustically shielded, precordial radiostethoscope that enables the anesthetist to follow the heart tones and breath sounds of the patient regardless of the anesthetist's location in the operating room. We compared our acoustically shielded device with a similar, but acoustically unshielded, commercially available device. We found the sound quality of our radiostethoscope to be superior to that of the commercial device; the signal-to-noise ratio of our device was 7.6 for heart tones and 8.4 for breath sounds, whereas the commercial device had a signal-to-noise ratio of 2.7 and 3.9 for heart tones and breath sounds, respectively. Our device offers all of the advantages of a radiostethoscope and has the added advantages of low cost and high fidelity.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Little, Brown and Company, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Equipment</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">precordial stethoscope</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">stethoscopy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mizutani</subfield>
   <subfield code="D">Alan</subfield>
   <subfield code="u">Department of Anesthesiology, UCSD Medical Center, 225 Dickinson St, 92103, San Diego, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ozaki</subfield>
   <subfield code="D">George</subfield>
   <subfield code="u">Department of Anesthesiology, UCSD Medical Center, 225 Dickinson St, 92103, San Diego, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Benumof</subfield>
   <subfield code="D">Jonathan</subfield>
   <subfield code="u">Department of Anesthesiology, UCSD Medical Center, 225 Dickinson St, 92103, San Diego, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/1(1990-01-01), 61-64</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:1&lt;61</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02832184</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02832184</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mizutani</subfield>
   <subfield code="D">Alan</subfield>
   <subfield code="u">Department of Anesthesiology, UCSD Medical Center, 225 Dickinson St, 92103, San Diego, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ozaki</subfield>
   <subfield code="D">George</subfield>
   <subfield code="u">Department of Anesthesiology, UCSD Medical Center, 225 Dickinson St, 92103, San Diego, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Benumof</subfield>
   <subfield code="D">Jonathan</subfield>
   <subfield code="u">Department of Anesthesiology, UCSD Medical Center, 225 Dickinson St, 92103, San Diego, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/1(1990-01-01), 61-64</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:1&lt;61</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
