<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465825702</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112148.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02832146</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02832146</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Meyer</subfield>
   <subfield code="D">Ronald</subfield>
   <subfield code="u">Department of Anesthesia, Northwestern University Medical School and Columbus Hospital, Chicago, IL</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Oxygen analyzers: Failure rates and life spans of galvanic cells</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Ronald Meyer]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Competing technologies exist for measuring oxygen concentrations in breathing circuits. Over a 4-year period, two types of oxygen analyzers were studied prospectively in routine clinical use to determine the incidence and nature of malfunctions. Newer AC-powered galvanic analyzers (North American DrÄger O2med) were compared with older, batterypowered polarographic analyzers (Ohmeda 201) by recording all failures and necessary repairs. The AC-powered galvanic analyzer had a significantly lower incidence of failures (0.12 ±0.04 failures per machine-month) than the battery-powered polarographic analyzer (4.0 ± 0.3 failures per machinemonth). Disposable capsules containing the active galvanic cells lasted 12 ± 7 months. Although the galvanic analyzers tended to remain out of service longer, awaiting the arrival of costly parts, the polarographic analyzers were more expensive to keep operating when calculations included the cost of time spent on repairs. Stocking galvanic capsules would have decreased the amount of time the galvanic analyzers were out of service, while increasing costs. In conclusion, galvanic oxygen analyzers appear capable of delivering more reliable service at a lower overall cost. By keeping the galvanic capsules exposed to room air during periods of storage, it should be possible to prolong their life span, further decreasing the cost of using them. In addition, recognizing the aberrations in their performance that warn of the exhaustion of the galvanic cells should permit timely reordering and minimize downtime.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Little, Brown and Company, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Monitoring: Equipment: analyzers</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">oxygen</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/3(1990-07-01), 196-202</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:3&lt;196</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02832146</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02832146</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Meyer</subfield>
   <subfield code="D">Ronald</subfield>
   <subfield code="u">Department of Anesthesia, Northwestern University Medical School and Columbus Hospital, Chicago, IL</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/3(1990-07-01), 196-202</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:3&lt;196</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
