<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">46582580X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112148.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02832147</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02832147</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Infrared analysis of volatile anesthetics: Impact of monitor agent setting, volatile mixtures, and Alcohol</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Douglas Guyton, Nikolaus Gravenstein]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Infrared analysis can determine exhaled concentrations of the three volatile anesthetics in common use because each absorbs infrared light. Many infrared analyzers use a single source of infrared light at a wavelength of 3.3 Μm for measurements of all three agents but cannot identify which agent is in use. Organic gases such as ethanol also absorb infrared light. This study determined the effects on the accuracy of a single-wavelength infrared anesthetic monitor (Capnomac, Puritan-Bennett PB254) of (1) incorrect anesthetic agent setting, (2) mixtures of volatile anesthetics, and (3) ethanol vapor in the analyzed gas. Changing the agent setting on the monitor during steady-state delivery of an agent resulted in readings for the halothane setting five times higher than those for the enflurane setting, and six times higher than those for the isoflurane setting. These ratios reflect the monitor's fixed internal gain for each agent setting. Mixtures of anesthetics had a simple additive effect on the monitor's accuracy. With the monitor set for halothane, 0.2 vol% isoflurane mixed with halothane caused readings 1.2 vol% higher than the true halothane concentration. Conversely, with the monitor set for isoflurane, 1 vol% halothane mixed with isoflurane resulted in readings 0.2 vol% too high. In a model simulating alveolar gas, ethanol vapor corresponding to blood alcohol levels of 0.10, 0.30, and 0.50% had a slight but not clinically significant effect on readings for enflurane and isoflurane but increased readings with the halothane setting 3.5 times the corresponding level of blood alcohol. Clinicians can test for an interfering gas such as ethanol before induction by checking the reading in the halothane setting during preoxygenation.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Little, Brown and Company, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Anesthetics: volatile</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Measurement techniques: infrared</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Equipment: vaporizers</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Guyton</subfield>
   <subfield code="D">Douglas</subfield>
   <subfield code="u">Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Gravenstein</subfield>
   <subfield code="D">Nikolaus</subfield>
   <subfield code="u">Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/3(1990-07-01), 203-206</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:3&lt;203</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02832147</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02832147</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Guyton</subfield>
   <subfield code="D">Douglas</subfield>
   <subfield code="u">Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Gravenstein</subfield>
   <subfield code="D">Nikolaus</subfield>
   <subfield code="u">Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/3(1990-07-01), 203-206</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:3&lt;203</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
