<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465825907</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112149.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19901001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02842485</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02842485</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperature</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Peter Freund, George Brengelmann]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The esophageal stethoscope has evolved into a device for both acoustic and core temperature monitoring. To test whether routine placement according to acoustic criteria results in placement of the core temperature sensor in the region of contiguity between the esophagus and the heart, we determined the depth of placement electrocardiographically. All patients were undergoing nonthoracic elective operations requiring general anesthesia and tracheal intubation. First, we established that different observers selected the same esophageal depth within ±1 cm electrocardiographically, using the criterion of a symmetric biphasic P wave of maximal amplitude (7 patients). Then, in 30 more patients, we compared routine acoustic placements with the depths of the maximalamplitude biphasic P wave. Stethoscopes placed according to acoustic criteria were within ±3 cm of P-wave depths in 15 of 30 patients. In the remaining patients, measured discrepancies ranged up to 13.5 cm. We conclude that the prevailing stethoscope design, with a thermistor at the tip, below the acoustic window, does not ensure placement of the thermistor within the optimal region for monitoring of core temperature. A modification in design that would take advantage of the reliability of electrocardiographic positioning is suggested.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Little, Brown and Company, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Monitoring: temperature</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Equipment: stethoscope, esophageal</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Freund</subfield>
   <subfield code="D">Peter</subfield>
   <subfield code="u">Departments of Anesthesiology and Physiology and Biophysics, University of Washington, and Anesthesiology Service, Veterans Administration Medical Center, Seattle, WA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Brengelmann</subfield>
   <subfield code="D">George</subfield>
   <subfield code="u">Departments of Anesthesiology and Physiology and Biophysics, University of Washington, and Anesthesiology Service, Veterans Administration Medical Center, Seattle, WA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/4(1990-10-01), 266-270</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:4&lt;266</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02842485</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02842485</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Freund</subfield>
   <subfield code="D">Peter</subfield>
   <subfield code="u">Departments of Anesthesiology and Physiology and Biophysics, University of Washington, and Anesthesiology Service, Veterans Administration Medical Center, Seattle, WA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Brengelmann</subfield>
   <subfield code="D">George</subfield>
   <subfield code="u">Departments of Anesthesiology and Physiology and Biophysics, University of Washington, and Anesthesiology Service, Veterans Administration Medical Center, Seattle, WA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/4(1990-10-01), 266-270</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:4&lt;266</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
