<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465825966</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112149.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19901001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02842487</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02842487</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Pennock</subfield>
   <subfield code="D">Bernard</subfield>
   <subfield code="u">Pulmonary Division, Allegheny General Hospital, 320 E North Ave, 15212, Pittsburgh, PA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Rib cage and abdominal piezoelectric film belts to measure ventilatory airflow</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Bernard Pennock]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Piezoelectric film-based respiratory belts are described and tested. To the extent that a two-degree of freedom model consisting of rib cage and abdominal motion is able to assist in quantifying ventilation, the piezoelectric belts can monitor flow in a manner analogous to the monitoring of volume with two magnetometer pairs or two respiratory inductive plethysmograph belts. The piezoelectric belts are shown to measure flow linearly when compared with a screen pneumotachometer to a flow of at least 2.6 L/s. There is no phase shift between the peak flow of belts and the pneumotachometer up to a frequency of at least 9.2 Hz. During normal ventilation, 68 and 95% of the peak flows measured with the belts fall within ±10 and 20%, respectively, of the flows measured with a screen pneumotachometer.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Little, Brown and Company, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Measurement techniques: plethysmography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Monitoring: ventilation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/4(1990-10-01), 276-283</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:4&lt;276</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02842487</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02842487</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pennock</subfield>
   <subfield code="D">Bernard</subfield>
   <subfield code="u">Pulmonary Division, Allegheny General Hospital, 320 E North Ave, 15212, Pittsburgh, PA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/4(1990-10-01), 276-283</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:4&lt;276</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
