<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">465826105</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323112149.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170327e19900401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02828282</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02828282</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Effect of anemia on pulse oximeter accuracy at low saturation</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[John Severinghaus, Shin Koh]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A retrospective evaluation of simultaneous tests of oximeters of various manufacturers in volunteer subjects disclosed greater errors at low saturations in subjects with low hemoglobin (Hb) concentrations. Forty-three pulse oximcters of 12 manufacturers studied over a period of 10 months showed that, at a mean arterial oxygen saturation (SaO2) level of 54.5%, as Hb concentration fell, average pulse oximeter (SpO2) bias increased approximately linearly from 0 at Hb &gt; 14 g/dl to about -14% at 8 &lt; Hb &lt; 9 g/dl. At SaO2 = 53.6%, the mean bias (SaO2-SpO2) of 13 oximcters of 5 manufacturers averaged -15.0% (n = 43) in a subject with Hb = 8 g/dl, but -6.4% (n = 390) in nonanemic subjects. The additional bias in the anemic subject increased with desaturation. It was 0.13% at SaO2 = 98.5% (n = 13), -1.31% at 87.5% (n = 38), -2.71% at 75.1% (n = 38), -5.18% at 61.3% (n = 26), and -9.95% at 53.6% (n = 41); n is the product of the number of oximeters and number of tests in each saturation range. The instruments that showed the greatest errors at low saturations in nonanemic subjects also showed the greatest additional errors associated with anemia (the range between manufacturers of anemic incremental error at about 53% being from -3.2 to -14.5%) and conformed well to the relationship bias (anemic) = 1.35 × bias (normal)-8.18% (r = 0.94; Sy·x = 3.3%). The error due to anemia was zero at 97% SaO2 and became evident when SaO2 fell below 75%.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Little, Brown and Company, 1990</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Measurement techniques: pulse oximetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Blood: anemia</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Equipment: pulse oximeters</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Oxygen: saturation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hypoxia</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Severinghaus</subfield>
   <subfield code="D">John</subfield>
   <subfield code="u">Department of Anesthesia and the Cardiovascular Research Institute, University of California, San Francisco, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Koh</subfield>
   <subfield code="D">Shin</subfield>
   <subfield code="u">Department of Anesthesia and the Cardiovascular Research Institute, University of California, San Francisco, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/2(1990-04-01), 85-88</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:2&lt;85</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02828282</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02828282</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Severinghaus</subfield>
   <subfield code="D">John</subfield>
   <subfield code="u">Department of Anesthesia and the Cardiovascular Research Institute, University of California, San Francisco, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Koh</subfield>
   <subfield code="D">Shin</subfield>
   <subfield code="u">Department of Anesthesia and the Cardiovascular Research Institute, University of California, San Francisco, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">6/2(1990-04-01), 85-88</subfield>
   <subfield code="x">0748-1977</subfield>
   <subfield code="q">6:2&lt;85</subfield>
   <subfield code="1">1990</subfield>
   <subfield code="2">6</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
