<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467911991</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406152851.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060201xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00142-005-0339-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00142-005-0339-6</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Dienst</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Klinik für Orthopädie und orthopädische Chirurgie, Universitätsklinikum des Saarlandes, Homburg/Saar</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Operationstechnik der Hüftarthroskopie — Tipps und Tricks</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[M. Dienst]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Surgical technique of hip arthroscopy — tips and tricks</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Der Erfolg der technisch anspruchsvollen Hüftarthroskopie hängt im Wesentlichen von einer ausgereiften Operationstechnik ab. Bereits eine korrekte Lagerungstechnik trägt erheblich zu guten Arthroskopiebedingungen bei. Die Verwendung eines dicken Gegenzugstabs hat die postoperativ häufigen temporären Beschwerden im Leisten- und Genitalbereich deutlich reduziert. Eine dicke Polsterung und sichere Fixierung des Fußes ist wichtig, um Hautnervenirritationen und ein Herausrutschen des Fußes während der Arthroskopie unter Traktion zu vermeiden. Traktionsdauer und -kraft sollten kritisch überwacht werden. Ein Röntgenbildverstärker sollte zumindest für die Erstportalanlage verwendet werden, auch zur weiteren Portalanlage kann sein Einsatz sehr hilfreich sein. Bei der Portalanlage zum zentralen Kompartiment kann die Luftarthrographie die Darstellung des Labrums und Femurkopfknorpels deutlich verbessern, sodass das Risiko einer Labrumperforation oder Knorpelschädigung reduziert wird. Zur diagnostischen und therapeutischen Hüftarthroskopie müssen Spezialinstrumente wie kanülierte Systeme und überlange Hand-, Motor- und HF-Instrumente vorhanden sein. Ein gutes Flüssigkeitsmanagement ist wichtig, um Blutungen zu beherrschen, Luftblasen aus dem Gelenk zu spülen und ein Weichteilödem zu vermeiden. Nur bei korrekter Portalanlage kann die Hüfte umfassend inspiziert und mögliche pathologische Veränderungen mit Instrumenten erreicht werden. Bei der risikoreicheren Portalanlage zum zentralen Kompartiment hat sich eine Technik bewährt, bei der die Erstportalanlage über das periphere Kompartiment arthroskopisch kontrolliert werden kann. Kapsulotomie und partielle Kapselresektionen stellen wichtige Optionen zur Verbesserung der Instrumentenbeweglichkeit und Sichtbedingungen dar. Vorteile bietet das portalhülsenfreie Einführen von Instrumenten, die über geschlitzte Kanülen eingebracht und gewechselt werden können.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hüfte</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Arthroskopie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Technik</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lagerung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instrumentarium</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hip</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Arthroscopy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Technique</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Positioning</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instrumentation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00142-005-0339-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00142-005-0339-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dienst</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Klinik für Orthopädie und orthopädische Chirurgie, Universitätsklinikum des Saarlandes, Homburg/Saar</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
