<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467912424</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406152852.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060101xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00117-005-1287-x</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00117-005-1287-x</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Glaser</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Knorpelbildgebung</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[C. Glaser]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Imaging of cartilage</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Übergeordnetes Therapieziel bei Knorpelschäden ist die Gewährleistung der optimal möglichen Gelenkfunktionalität durch Erhaltung bzw. Wiederherstellung einer stabilen Kongruenz und einer ausgeglichenen mechanischen Belastungssituation im Gelenk. Aufgabe der Magnetresonanztomographier (MRT) ist es, Zahl, Tiefe und flächenhafte Ausdehnung von Knorpelveränderungen und deren Verteilung über die verschiedenen Gelenkkompartimente zu beschreiben. Für eine adäquate Knorpeldiagnostik in der MRT ist eine hohe räumliche Auflösung bei gutem Signal-zu-Rausch-Verhältnis (SNR) und gutem Kontrast zum Gelenkbinnenraum und zum subchondralen Knochen nötig. Letzterer ergibt sich bei TSE-Sequenzen für Echozeiten um 30-50ms. Die Darstellung von Läsionen in mehreren Ebenen erhöht die Treffsicherheit. Kurze Echozeit, hohe Bandbreite und geeignete Wahl der Frequenzkodierrichtung tragen zur Minimierung von Metallartefakten bei. Moderate T2w-TSE-Sequenzen stellen Binnenveränderungen am Knorpel, subchondrale Knochenmarködem-ähnliche Areale als Hinweis auf etwaige benachbarte Knorpelläsionen und Erguss, der Knorpeldefekte kontrastreich konturiert, sensitiv dar. Die Stärke der T1w-FS/WE-3D-GE-Sequenzen ist ihre hohe räumliche Auflösung, die die graduelle Erfassung von Knorpelerosionen unterstützt. Kriterien zur Beurteilung der Stabilität bei Osteochondrosis dissecans (OD) sind die Grenzfläche zum umgebenden Knochen, die Integrität der Knorpeloberfläche und assoziierte zystische Veränderungen. Die Treffsicherheit steigt, wenn mehrere Kriterien zusammentreffen, die Prognose ist assoziiert mit der Größe des betroffenen Areals.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2005</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Gelenkfunktionalität</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnetresonanztomographie (MRT)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Metallartefakte</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Stabilität</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Joint motion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnetic resonance imaging (MRI)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Metallic artifacts</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Stability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00117-005-1287-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00117-005-1287-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Glaser</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
