<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467912564</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406152853.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060901xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00117-006-1353-z</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00117-006-1353-z</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Wanivenhaus</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Universitätsklinik für Orthopädie, Medizinische Universität, Währinger Gürtel 18-20, A-1090, Wien, Österreich</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Implantate der Hand</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Wanivenhaus]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Implants in the hand</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Implantate im Bereich der Gelenke der Hand und des Handgelenks stellen zunehmend Alternativen bei der Versorgung posttraumatischer, entzündlicher oder degenerativer Gelenkschäden dar. Die Vielfalt der Handfunktionen führt auch zu unterschiedlichen Lösungen, die durch Stabilität, Mobilität und Distraktion wirksam werden. Dafür sind unterschiedliche Materialien erforderlich, die eine subtile radiologische Kontrolle erfordern. Das Nativröntgen stellt das wesentlichste Verfahren zur Verlaufsbeobachtung von Implantaten dar. Das Interface zwischen Titan, Keramik, Zirkonium, Pyrokarbon und Silikon zum Knochen muss unterschiedlich bewertet werden, um relevante Aussagen treffen zu können. Die Fingergelenke und in begrenztem Ausmaß auch das Handgelenk stellen Kunstgelenke mit geringen Alternativtherapiemöglichkeiten dar. Die übrigen Implantate der Hand sollten nur bei strenger Indikationsstellung und hoher Patientencompliance Anwendung finden, da Arthrodese oder Resektionsarthroplastik gute Langzeitresultate aufweisen.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Handimplantate</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Resektionsarthroplastik</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Silikonspacer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Kunstgelenk</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hand implants</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Arthroplasty</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Siliconspacer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Artificial joint</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00117-006-1353-z</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00117-006-1353-z</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wanivenhaus</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Universitätsklinik für Orthopädie, Medizinische Universität, Währinger Gürtel 18-20, A-1090, Wien, Österreich</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
