<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">46791303X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406152854.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20061001xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00117-006-1374-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00117-006-1374-7</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Neue Techniken in der Osteoporosediagnostik</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Issever, T. Link]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">New techniques for the diagnosis of osteoporosis</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: In der vorliegenden Arbeit werden die aktuellen Entwicklungen und Anwendungen auf dem Gebiet der radiologischen Osteoporosediagnostik vorgestellt. Weiterentwicklungen bzgl. der dualen Röntgenabsorptiometrie (dual energy x-ray absorptiometry, DXA) beinhalten geometrische Parameter des proximalen Femurs wie die &quot;hip axis length&quot; und neue Zielregionen (regions of interest, ROIs) zur Messung der Knochenmineraldichte (bone mineral density, BMD). Im Bereich der quantitativen Computertomographie (QCT) wurde gezeigt, dass nach Anwendung eines Konversionsfaktors die BMD auch aus klinischen abdominellen CTs ähnlich der QCT erfasst werden kann. Auch werden zunehmend volumetrische Methoden der BMD-Messung an der Wirbelsäule und dem proximalen Femur eingesetzt. In den letzten Jahren war im Rahmen des neu entwickelten Knochenqualitätskonzepts die Bestimmung der Knochenarchitektur ein zentraler Fokus. Die trabekuläre Strukturanalyse mittels hochauflösender Verfahren wie der Magnetresonanztomographie und neuer computertomographischer Techniken wird daher in Zukunft für die Osteoporose an Bedeutung zunehmen. Mit dem quantitativen Ultraschall steht eine relativ preiswerte Methode zur Diagnostik der Knochenqualität zur Verfügung. Mit diesen neuen Techniken ist in den nächsten Jahren von einem Paradigmenwechsel in der quantitativen Osteoporosediagnostik auszugehen.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Osteoporose</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Knochenmineraldichte (bone mineral density, BMD)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Bildgebung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnetresonanztomographie (MRT)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Strukturanalyse</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Trabekulärer Knochen</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Osteoporosis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Bone mineral density (BMD)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Imaging</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnetic resonance imaging (MRI)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Structure analysis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Trabecular bone</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Issever</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Institut für Radiologie am Campus Mitte, Klinikum Charité der Universitätsmedizin Berlin</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Link</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Department of Radiology, University of California, 400 Parnassus Ave (A-367), San Francisco, CA 94143, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00117-006-1374-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00117-006-1374-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Issever</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Institut für Radiologie am Campus Mitte, Klinikum Charité der Universitätsmedizin Berlin</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Link</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Department of Radiology, University of California, 400 Parnassus Ave (A-367), San Francisco, CA 94143, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
