<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467913137</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406152854.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060401xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00117-005-1325-8</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00117-005-1325-8</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">MRT der Lungenperfusion</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[C. Fink, F. Risse, W. Semmler, S. Schoenberg, H.-U. Kauczor, M. Reiser]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">MRI of pulmonary perfusion</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Die Perfusion der Lunge ist eine entscheidende Voraussetzung für einen effektiven Gasaustausch. Die Bestimmung der Lungenperfusion ist bei verschiedenen Erkrankungen der Lunge für Diagnostik und Therapieplanung bedeutsam. Hierzu zählen neben Erkrankungen der Lungengefäße wie akute Lungenembolie und pulmonale Hypertension ebenso Erkrankungen der Atemwege, des Lungengerüsts und Lungentumoren. In diesem Beitrag werden die Möglichkeiten und technischen Voraussetzungen der MRT zur Diagnostik der Lungenperfusion dargestellt.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Medizin Verlag, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnetresonanztomographie (MRT)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lunge</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Perfusion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Perfusionsszintigraphie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lungenembolie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnetic resonance imaging (MRI)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Perfusion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Perfusion scintigraphy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pulmonary embolism</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fink</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Risse</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Abteilung Medizinische Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Semmler</subfield>
   <subfield code="D">W.</subfield>
   <subfield code="u">Abteilung Medizinische Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schoenberg</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kauczor</subfield>
   <subfield code="D">H.-U</subfield>
   <subfield code="u">Abteilung Radiologie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Reiser</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00117-005-1325-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00117-005-1325-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fink</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Risse</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Abteilung Medizinische Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Semmler</subfield>
   <subfield code="D">W.</subfield>
   <subfield code="u">Abteilung Medizinische Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schoenberg</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kauczor</subfield>
   <subfield code="D">H.-U</subfield>
   <subfield code="u">Abteilung Radiologie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Reiser</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Institut für Klinische Radiologie, Klinikum Großhadern der Ludwig-Maximilians-Universität München</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
