<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467930775</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406152942.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060601xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10706-004-4006-x</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10706-004-4006-x</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Compressibility and Strength Behaviour of Sand-tyre Chip Mixtures</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[G. Rao, R. Dutta]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Scrap tyres can be shredded into chips and can easily be mixed with granular soils. To assess the behaviour of the admixtures, compressibility and triaxial compression tests were carried out by varying chip size and chip content. The results demonstrated that sand-tyre chip mixtures up to 20% could be a potential material for highway construction and embankment construction up to around 10 m height.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer, 2006</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">compressibility tests</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">repeated load tests</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">sand</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">triaxial test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">tyre chips</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Rao</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Department of Civil Engineering, Indian Institute of Technology, 110016, Hauz Khas, New Delhi, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Dutta</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Department of Civil Engineering, National Institute of Technology, 177005, Hamirpur, HP, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Geotechnical &amp; Geological Engineering</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">24/3(2006-06-01), 711-724</subfield>
   <subfield code="x">0960-3182</subfield>
   <subfield code="q">24:3&lt;711</subfield>
   <subfield code="1">2006</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">10706</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10706-004-4006-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10706-004-4006-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Rao</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Department of Civil Engineering, Indian Institute of Technology, 110016, Hauz Khas, New Delhi, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dutta</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Department of Civil Engineering, National Institute of Technology, 177005, Hamirpur, HP, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Geotechnical &amp; Geological Engineering</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">24/3(2006-06-01), 711-724</subfield>
   <subfield code="x">0960-3182</subfield>
   <subfield code="q">24:3&lt;711</subfield>
   <subfield code="1">2006</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">10706</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
