<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467941122</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406153013.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00421-005-0090-8</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00421-005-0090-8</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Maximal lactate steady state concentration independent of pedal cadence in active individuals</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Benedito Denadai, Vinícius Ruas, Tiago Figueira]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The maximal lactate steady state (MLSS) is defined as the highest blood lactate concentration that can be maintained over time without a continual blood lactate accumulation. The objective of the present study was to analyze the effects of pedal cadence (50 vs. 100revmin−1) on MLSS and the exercise workload at MLSS (MLSSworkload) during cycling. Nine recreationally active males (20.9±2.9years, 73.9±6.5kg, 1.79±0.09m) performed an incremental maximal load test (50 and 100revmin−1) to determine anaerobic threshold (AT) and peak workload (PW), and between two and four constant submaximal load tests (50 and 100revmin−1) on a mechanically braked cycle ergometer to determine MLSSworkload and MLSS. MLSSworkload was defined as the highest workload at which blood lactate concentration did not increase by more than 1mM between minutes 10 and 30 of the constant workload. The maximal lactate steady state intensity (MLSSintensity) was defined as the ratio between MLSSworkload and PW. MLSSworkload (186.1±21.2W vs. 148.2±15.5W) and MLSSintensity (70.5±5.7% vs. 61.4±5.1%) were significantly higher during cycling at 50revmin−1 than at 100revmin−1, respectively. However, there was no significant difference in MLSS between 50revmin−1 (4.8±1.6mM) and 100revmin−1 (4.7±0.8mM). We conclude that MLSSworkload and MLSSintensity are dependent on pedal cadence (50 vs. 100revmin−1) in recreationally active individuals. However, this study showed that MLSS is not influenced by the different pedal cadences analyzed.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2005</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Cycling</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Oxidative metabolism</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Constant workload test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Denadai</subfield>
   <subfield code="D">Benedito</subfield>
   <subfield code="u">Laboratório de Avaliação da Performance Humana, UNESP, Av. 24 A, 1515, Bela Vista, CEP 13506-900, Rio Claro, SP, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ruas</subfield>
   <subfield code="D">Vinícius</subfield>
   <subfield code="u">Laboratório de Avaliação da Performance Humana, UNESP, Av. 24 A, 1515, Bela Vista, CEP 13506-900, Rio Claro, SP, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Figueira</subfield>
   <subfield code="D">Tiago</subfield>
   <subfield code="u">Laboratório de Avaliação da Performance Humana, UNESP, Av. 24 A, 1515, Bela Vista, CEP 13506-900, Rio Claro, SP, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">European Journal of Applied Physiology</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">96/4(2006-03-01), 477-480</subfield>
   <subfield code="x">1439-6319</subfield>
   <subfield code="q">96:4&lt;477</subfield>
   <subfield code="1">2006</subfield>
   <subfield code="2">96</subfield>
   <subfield code="o">421</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00421-005-0090-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">brief-communication</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00421-005-0090-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Denadai</subfield>
   <subfield code="D">Benedito</subfield>
   <subfield code="u">Laboratório de Avaliação da Performance Humana, UNESP, Av. 24 A, 1515, Bela Vista, CEP 13506-900, Rio Claro, SP, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ruas</subfield>
   <subfield code="D">Vinícius</subfield>
   <subfield code="u">Laboratório de Avaliação da Performance Humana, UNESP, Av. 24 A, 1515, Bela Vista, CEP 13506-900, Rio Claro, SP, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Figueira</subfield>
   <subfield code="D">Tiago</subfield>
   <subfield code="u">Laboratório de Avaliação da Performance Humana, UNESP, Av. 24 A, 1515, Bela Vista, CEP 13506-900, Rio Claro, SP, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">European Journal of Applied Physiology</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">96/4(2006-03-01), 477-480</subfield>
   <subfield code="x">1439-6319</subfield>
   <subfield code="q">96:4&lt;477</subfield>
   <subfield code="1">2006</subfield>
   <subfield code="2">96</subfield>
   <subfield code="o">421</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
