<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">467941149</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406153013.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e20060301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00421-005-0086-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00421-005-0086-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Maximal lactate steady state determination with a single incremental test exercise</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[David Laplaud, Michel Guinot, Anne Favre-Juvin, Patrice Flore]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The aim of this study was to determine whether the power output associated with a maximal lactate steady state (MLSS) (ẆMLSS) can be assessed using a single incremental cycling test. Eleven recreational sportsmen (age: 22±1years, height: 175±6cm, weight: 71±5kg) volunteered to participate in the study. For each subject the first and second ventilatory thresholds (VT1 and VT2, respectively) and the power output corresponding to (respiratory exchange ratio) RER=1.00 were determined during an incremental test to exhaustion. Thereafter, each subject performed several 30-min constant load tests to determine MLSS. The workload used in the first constant test was set to the ẆRER=1.00 determined during the incremental test. ẆVT1 (175±24W) and ẆVT2 (265±31W) were significantly different from ẆMLSS (220±36W). Whereas, ẆRER=1.00 (224±33W) was similar to ẆMLSS. HR, RER and V̇E were significantly different between the 10th and the 30th minutes when exercising at ẆRER=1.00 and at ẆMLSS. In contrast, V̇O2 and V̇CO2 were stable over those 30-min constant tests. Power output at VT1, RER=1.00 and VT2 were all correlated to ẆMLSS but the relationship was stronger between RER=1.00 and MLSS (R 2=0.95). The present study shows that the power output associated with a RER value equal to 1.00 during an incremental test does not differ from that determined for MLSS. Hence, the MLSS can be estimated with a single exercise test.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2005</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Respiratory exchange ratio</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Incremental test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Constant test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Blood lactate</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Laplaud</subfield>
   <subfield code="D">David</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Guinot</subfield>
   <subfield code="D">Michel</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Favre-Juvin</subfield>
   <subfield code="D">Anne</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Flore</subfield>
   <subfield code="D">Patrice</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">European Journal of Applied Physiology</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">96/4(2006-03-01), 446-452</subfield>
   <subfield code="x">1439-6319</subfield>
   <subfield code="q">96:4&lt;446</subfield>
   <subfield code="1">2006</subfield>
   <subfield code="2">96</subfield>
   <subfield code="o">421</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00421-005-0086-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00421-005-0086-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Laplaud</subfield>
   <subfield code="D">David</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Guinot</subfield>
   <subfield code="D">Michel</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Favre-Juvin</subfield>
   <subfield code="D">Anne</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Flore</subfield>
   <subfield code="D">Patrice</subfield>
   <subfield code="u">UF de Biologie et Médecine du Sport, Service EFCR Pr Lévy, CHU Grenoble, BP 185, 38042, Grenoble Cedex 09, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">European Journal of Applied Physiology</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">96/4(2006-03-01), 446-452</subfield>
   <subfield code="x">1439-6319</subfield>
   <subfield code="q">96:4&lt;446</subfield>
   <subfield code="1">2006</subfield>
   <subfield code="2">96</subfield>
   <subfield code="o">421</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
