<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">469040017</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323132808.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e19920501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00137253</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00137253</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Eschermann</subfield>
   <subfield code="D">Bernhard</subfield>
   <subfield code="u">University of Siegen, FB12-Rechnerstruleturev, Hoelderlivstr.3, 5900, Siegen, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="3">
   <subfield code="a">An implicitly testable boundary scan TAP controller</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Bernhard Eschermann]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The design of a test access port controller conforming to the boundary scan standard is described, which is implicitly tested while it is working. It is based on a novel self-test technique also applicable to other controller designs. This technique uses a signature register as state register, such that no reconfiguration of that register is necessary during self-test. This way the test of the test access port can be efficiently incorporated into the system self-test. No additional I/O pins beyond those of the boundary scan standard are necessary, neither does the test program have to be changed to incorporate the test of the controller. The solution only requires moderate hardware overheads, nevertheless it guarantees a high fault coverage.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Kluwer Academic Publishers, 1992</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">BIST</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">boundary scan</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">controller design</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">self-test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">synthesis for testability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">test controller</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Electronic Testing</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">3/2(1992-05-01), 159-169</subfield>
   <subfield code="x">0923-8174</subfield>
   <subfield code="q">3:2&lt;159</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">3</subfield>
   <subfield code="o">10836</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00137253</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00137253</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Eschermann</subfield>
   <subfield code="D">Bernhard</subfield>
   <subfield code="u">University of Siegen, FB12-Rechnerstruleturev, Hoelderlivstr.3, 5900, Siegen, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Electronic Testing</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">3/2(1992-05-01), 159-169</subfield>
   <subfield code="x">0923-8174</subfield>
   <subfield code="q">3:2&lt;159</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">3</subfield>
   <subfield code="o">10836</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
