<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">469109858</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323133107.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e19921001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02035400</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02035400</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Speciation and estimation of radioiodine in reactor coolant water</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[P. Ravi, K. Neelakandhan, M. Iyer]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The species of radioiodine in the primary coolant water of the heavy water moderated, heavy water cooled 100 MW research reactor have been identified. It was observed that IO 3 − was the major species in the reactor coolant during reactor operation and I− was the major species during shutdown. Organic and elemental forms amount only to less than 2% of total radioiodine. A simple method was developed for the estimation of gross iodine activity in reactor coolant water. The method involves the separation of all inorganic forms of iodine into a photographic film consisting of a thin layer of silver halide. The iodine in the film was estimated by gross counting of the film in a Geiger-Müller counter. Gross iodine activity in the reactor coolant samples estimated by the present method were in agreement with that obtained by direct γ-spectrometry with a Ge detector. It is concluded that the method can be used for the routine estimation of radioiodine in reactor coolant water.133I/131I and135I/131I ratios in the film were estimated and found to be useful in identifying split rod conditions in the reactor.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Akadémiai Kiadó, 1992</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ravi</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Radioation Safety Systems Division, Bhabha Atomic Research Centre, 400085, Bombay, (India)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Neelakandhan</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Radioation Safety Systems Division, Bhabha Atomic Research Centre, 400085, Bombay, (India)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Iyer</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Radioation Safety Systems Division, Bhabha Atomic Research Centre, 400085, Bombay, (India)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Radioanalytical and Nuclear Chemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">162/2(1992-10-01), 399-405</subfield>
   <subfield code="x">0236-5731</subfield>
   <subfield code="q">162:2&lt;399</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">162</subfield>
   <subfield code="o">10967</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02035400</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02035400</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ravi</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Radioation Safety Systems Division, Bhabha Atomic Research Centre, 400085, Bombay, (India)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Neelakandhan</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Radioation Safety Systems Division, Bhabha Atomic Research Centre, 400085, Bombay, (India)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Iyer</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Radioation Safety Systems Division, Bhabha Atomic Research Centre, 400085, Bombay, (India)</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Radioanalytical and Nuclear Chemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">162/2(1992-10-01), 399-405</subfield>
   <subfield code="x">0236-5731</subfield>
   <subfield code="q">162:2&lt;399</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">162</subfield>
   <subfield code="o">10967</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
