<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">46912279X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323133143.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e19920701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02368135</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02368135</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Kichul Cha, Kenneth Horch, Richard Normann]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A visual prosthesis for the blind using electrical stimulation of the visual cortex will require the development of an array of electrodes. Passage of current through these electrodes is expected to create a visual image made up of a matrix of discrete phosphenes. The quality of the visual sense thus provided will be a function of many parameters, particularly the number of electrodes and their spacing. We are conducting a series of psychophysical experiments with a portable &quot;phosphene” simulator to obtain estimates of suitable values for electrode number and spacing. The simulator consists of a small video camera and monitor worn by a normally sighted human subject. To simulate a discrete phosphene field, the monitor is masked by an opaque perforated film. The visual angle subtended by images from the masked monitor is 1.7° or less, depending on the mask, and falls within the fovea of the subject. In the study presented here, we measured visual acuity as a function of the number of pixels and their spacing in the mask. Visual acuity was inversely proportional to pixel density, and trained subjects could achieve about 20/26 visual acuity with a 1024 pixel image. We conclude that 625 electrodes implanted in a 1 cm by 1 cm area near the foveal representation of the visual cortex should produce a phosphene image with a visual acuity of approximately 20/30. Such an acuity could provide useful restoration of functional vision for the profoundly blind.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pergamon Press Ltd., 1992</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Phosphene simulation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Visual prosthesis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Visual acuity</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cha</subfield>
   <subfield code="D">Kichul</subfield>
   <subfield code="u">Department of Bioengineering, University of Utah, 84112, Salt Lake City, UT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Horch</subfield>
   <subfield code="D">Kenneth</subfield>
   <subfield code="u">Department of Bioengineering, University of Utah, 84112, Salt Lake City, UT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Normann</subfield>
   <subfield code="D">Richard</subfield>
   <subfield code="u">Department of Bioengineering, University of Utah, 84112, Salt Lake City, UT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Annals of Biomedical Engineering</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">20/4(1992-07-01), 439-449</subfield>
   <subfield code="x">0090-6964</subfield>
   <subfield code="q">20:4&lt;439</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">10439</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02368135</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02368135</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cha</subfield>
   <subfield code="D">Kichul</subfield>
   <subfield code="u">Department of Bioengineering, University of Utah, 84112, Salt Lake City, UT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Horch</subfield>
   <subfield code="D">Kenneth</subfield>
   <subfield code="u">Department of Bioengineering, University of Utah, 84112, Salt Lake City, UT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Normann</subfield>
   <subfield code="D">Richard</subfield>
   <subfield code="u">Department of Bioengineering, University of Utah, 84112, Salt Lake City, UT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Annals of Biomedical Engineering</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">20/4(1992-07-01), 439-449</subfield>
   <subfield code="x">0090-6964</subfield>
   <subfield code="q">20:4&lt;439</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">10439</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
