<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">46912282X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323133143.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e19920901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02368173</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02368173</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Tehrani</subfield>
   <subfield code="D">Fleur</subfield>
   <subfield code="u">Department of Electrical Engineering, California State University, 92634, Fullerton, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="2">
   <subfield code="a">A microcomputer oxygen control system for ventilatory therapy</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Fleur Tehrani]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the controller has been tested using a dynamic, mathematical model of the human respiratory system. This relatively sophisticated model has been developed and examined in the past, and it has been shown that it can realistically describe the human respiratory system for a wide variety of test conditions. The performance of the oxygen control system has been evaluated using the simulation model. The response of the controller to different disturbances is always stable, with arterial pressure of oxygen returning to normal in less than 12 minutes. Some of the simulation results are presented to illustrate the dynamic behavior and robustness of the controller.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pergamon Press Ltd, 1992</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Feedback control</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Artificial ventilation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Computer simulation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Arterial oxygen saturation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Annals of Biomedical Engineering</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">20/5(1992-09-01), 547-558</subfield>
   <subfield code="x">0090-6964</subfield>
   <subfield code="q">20:5&lt;547</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">10439</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02368173</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02368173</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Tehrani</subfield>
   <subfield code="D">Fleur</subfield>
   <subfield code="u">Department of Electrical Engineering, California State University, 92634, Fullerton, CA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Annals of Biomedical Engineering</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">20/5(1992-09-01), 547-558</subfield>
   <subfield code="x">0090-6964</subfield>
   <subfield code="q">20:5&lt;547</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">10439</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
