<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">469129816</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180323133201.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170328e19920901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00324838</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00324838</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Voltammetric determination of pentachlorophenol with a silica gel-modified carbon paste electrode</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[M. Ruiz Barrio, J. Pingarrón Carrazón]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Summary: The anodic voltammetric behaviour of pentachlorophenol at a silica gel-modified carbon paste electrode in aqueous solution is reported. Adsorption of the fungicide onto the electrode under open-circuit conditions is followed by application of either differential or square wave voltammetry. The results obtained by differential pulse voltammetry at pH 2.9, with a modifier concentration of 10% and accumulation times of 120 and 300 s, allowed the development of a method to determine pentachlorophenol in the ranges of 1.0×10−6-1.0×10−5 and 1.0×10−7-1.0×10−6 mol l−1. The relative standard deviation is 2.6% for a concentration of 2.0×10−7 mol l−1, with a detection limit of 1.8×10−8 mol l−1 (5 ppb). The effect of other chlorophenols was studied. The results obtained by square wave voltammetry showed a behaviour typical of an irreversible electron transfer. Amplitude, step height and frequency were optimised, taking into account the resolution of the voltammetric response. No improvement in sensitivity was obtained with respect to DPV. Good results were obtained by applying the proposed differential-pulse voltammetric method to the determination of pentachlorophenol in a commercial fungicide.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 1992</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ruiz Barrio</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, E-28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pingarrón Carrazón</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, E-28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Fresenius' Journal of Analytical Chemistry</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">344/1-2(1992-09-01), 34-38</subfield>
   <subfield code="x">0937-0633</subfield>
   <subfield code="q">344:1-2&lt;34</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">344</subfield>
   <subfield code="o">216</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00324838</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00324838</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ruiz Barrio</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, E-28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pingarrón Carrazón</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, E-28040, Madrid, Spain</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Fresenius' Journal of Analytical Chemistry</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">344/1-2(1992-09-01), 34-38</subfield>
   <subfield code="x">0937-0633</subfield>
   <subfield code="q">344:1-2&lt;34</subfield>
   <subfield code="1">1992</subfield>
   <subfield code="2">344</subfield>
   <subfield code="o">216</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
