<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475748638</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123520.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1023/A:1005424910489</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1023/A:1005424910489</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Electromagnetic Interference with Electronic Medical Equipment Induced by Automatic Conveyance Systems</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Eisuke Hanada, Yoshiaki Watanabe, Yoshiaki Nose]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Electromagnetic interference (EMI) with electronic medical equipment induced by automatic conveyance systems is estimated. We measured the electric intensities of electromagnetic waves transmitted by three self-controlled electric truck systems. We also observed EMI with an infusion pump and a syringe pump set 1 m from the rail. The maximum electric field intensity was observed at the supplied current frequency in two systems with non-contact power supply mechanisms. The highest value, 137.0 dBμV/m, was measured just beside the rail. This is higher than the international electromagnetic immunity standard limit for electronic medical equipment. EMI may occur if electronic medical equipment is used within 2 m of the rail when the system contains an inductive power supply mechanism. With a contact power supply mechanism, the electric field intensity was much lower than that of the immunity standard. EMI should not occur even when electronic medical equipment is used just beside the rail.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">automated conveyance system</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">electromagnetic fields</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">electromagnetic interference</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">electronic medical equipment</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">non-contact power supply mechanism</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hanada</subfield>
   <subfield code="D">Eisuke</subfield>
   <subfield code="u">Department of Medical Information Science, Graduate School of Medical Science, Kyushu University, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Watanabe</subfield>
   <subfield code="D">Yoshiaki</subfield>
   <subfield code="u">Department of Information Science, Faculty of Science and Engineering, Saga University, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Nose</subfield>
   <subfield code="D">Yoshiaki</subfield>
   <subfield code="u">Department of Medical Information Science, Graduate School of Medical Science, Kyushu University, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Medical Systems</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">24/1(2000-02-01), 11-20</subfield>
   <subfield code="x">0148-5598</subfield>
   <subfield code="q">24:1&lt;11</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">10916</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1023/A:1005424910489</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1023/A:1005424910489</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hanada</subfield>
   <subfield code="D">Eisuke</subfield>
   <subfield code="u">Department of Medical Information Science, Graduate School of Medical Science, Kyushu University, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Watanabe</subfield>
   <subfield code="D">Yoshiaki</subfield>
   <subfield code="u">Department of Information Science, Faculty of Science and Engineering, Saga University, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Nose</subfield>
   <subfield code="D">Yoshiaki</subfield>
   <subfield code="u">Department of Medical Information Science, Graduate School of Medical Science, Kyushu University, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Medical Systems</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">24/1(2000-02-01), 11-20</subfield>
   <subfield code="x">0148-5598</subfield>
   <subfield code="q">24:1&lt;11</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">10916</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
