<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475748751</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123521.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000601xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1023/A:1005535224082</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1023/A:1005535224082</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Development of a Decision Support System to Assist Anesthesiologists in Operating Room</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Marina Krol, David Reich]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The complexity of modern anesthesia procedures requires the development of decision-support systems functioning in a smart-alarm capacity. We developed computer algorithms to detect critical conditions during surgery (light anesthesia or unstable blood pressure), based on computerized anesthesia records containing hemodynamic data (heart rate, mean arterial pressure and systolic arterial pressure). Our analysis indicated that a ≥12% change in mean arterial blood pressure (MAP), compared with the median value of MAP over the preceding 10-min interval, may be chosen as the criterion for detecting LA, with a sensitivity of 96% and a specificity of 91%. The best agreement between human and computer ratings of blood pressure lability (correlation coefficient 0.78) was achieved when we used the absolute value of the fractional change of the mean arterial pressure (|FCM|) between one 2-min epoch and the next 2-min epoch. Work is under progress to develop a decision-support system to alert clinicians in the operating room environment to critical events.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">modern anesthesia</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">smart-alarm capacity</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">computer algorithms</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Krol</subfield>
   <subfield code="D">Marina</subfield>
   <subfield code="u">Department of Anesthesiology, The Mount Sinai-School of Medicine, One Gustave L. Levy Place, Box 1010, 10029, New York, New York</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Reich</subfield>
   <subfield code="D">David</subfield>
   <subfield code="u">Department of Anesthesiology, The Mount Sinai-School of Medicine, One Gustave L. Levy Place, Box 1010, 10029, New York, New York</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Medical Systems</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">24/3(2000-06-01), 141-146</subfield>
   <subfield code="x">0148-5598</subfield>
   <subfield code="q">24:3&lt;141</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">10916</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1023/A:1005535224082</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1023/A:1005535224082</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Krol</subfield>
   <subfield code="D">Marina</subfield>
   <subfield code="u">Department of Anesthesiology, The Mount Sinai-School of Medicine, One Gustave L. Levy Place, Box 1010, 10029, New York, New York</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Reich</subfield>
   <subfield code="D">David</subfield>
   <subfield code="u">Department of Anesthesiology, The Mount Sinai-School of Medicine, One Gustave L. Levy Place, Box 1010, 10029, New York, New York</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Medical Systems</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">24/3(2000-06-01), 141-146</subfield>
   <subfield code="x">0148-5598</subfield>
   <subfield code="q">24:3&lt;141</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">10916</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
