<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475779401</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123640.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s004640020068</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s004640020068</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Ultrasound-based volumetric evaluation of fluid retention after inguinal hernia repair</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[C. Peiper, N. Ponschek, S. Truong, V. Schumpelick]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Background: Daily routine has shown that there are differences between the aspirated volumes of subcutaneous liquid retention after inguinal hernia repair and the results of sonographic-based volumetry using the standard rotating ellipsoid formula. Methods: In 83 patients, subcutaneous fluid retention after Shouldice repair was visualized by ultrasound and calculated as cuboid, cylinder, and rotating ellipsoid, respectively. The results were compared to the aspirated volume. Data were analyzed retrospectively. Results: The volume obtained by percutaneous punction averaged 12.18 ± 1.50 ml. The calculated volumes were distinctly less: cuboid, 11.98 ± 1.59 ml; cylinder, 10.26 ± 1.45 ml; rotating ellipsoid, 5.99 ± 0.80 ml. We found different coefficients of regression for the aspirated and the calculated volumes (cuboid; 0.75; cylinder; 0.82; rotating ellipsoid; 1.50). The coefficients of correlation, however, were 0.79 for all modes of calculation. Conclusion: Because its results were closest to the aspirated volumes, we recommend the cuboid formula for the ultrasound-based calculation of liquid retention after inguinal hernia repair.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag New York Inc., 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Key words: Hernia — Inguinal hernia repair — Liquid retention — Ultrasound — Volumetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Peiper</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ponschek</subfield>
   <subfield code="D">N.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Truong</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schumpelick</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Surgical Endoscopy</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">14/7(2000-07-01), 666-669</subfield>
   <subfield code="x">0930-2794</subfield>
   <subfield code="q">14:7&lt;666</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">14</subfield>
   <subfield code="o">464</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s004640020068</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s004640020068</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Peiper</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ponschek</subfield>
   <subfield code="D">N.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Truong</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schumpelick</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Surgical Clinic, RWTH Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Surgical Endoscopy</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">14/7(2000-07-01), 666-669</subfield>
   <subfield code="x">0930-2794</subfield>
   <subfield code="q">14:7&lt;666</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">14</subfield>
   <subfield code="o">464</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
