<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475779584</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123640.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s004640020077</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s004640020077</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">New instrumentation for video-assisted anterior spine release</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[T. Ohtsuka, I. Ohnishi, K. Nakamura, S. Takamoto]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Endoscopic surgery in the area of orthopedics has been evolving, particularly in spine surgery. We describe the clinical outcome of thoracoscopic anterior spine release using new instruments. A harmonic scalpel (HS) with a 5-mm hook dissector was used to dissect the spine and rib and to coagulate and transect the vascular bundles. A rib dissector and resector were used for excision of the rib to be implanted in the disk spaces. We treated scoliosis in four patients (three male, one female) with a mean age of 19.5 ± 4.5 years and thoracolumbar kyphosis in a 16-year-old male patient. A mean number of 6.5 ± 2.5 vertebrae with scoliosis and four vertebrae with kyphosis were released. In all cases, division of the vascular bundle and exposure of the spine were completed using only the HS, and excision of a rib segment was performed via a port incision using only the rib dissector and resector. The mean duration of thoracoscopic anterior release was 92 ± 28 min. Blood loss was minimal during and after surgery. Thoracoscopic anterior spine release can be facilitated by the new instruments described above.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag New York Inc., 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Key words: Anterior spine release — Harmonic scalpel — Orthopedics — Rib resector and dissector — Spine — Thoracoscopic surgery</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ohtsuka</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Department of Cardiothoracic Surgery, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ohnishi</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">Department of Orthopedics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Nakamura</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Department of Orthopedics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Takamoto</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Department of Cardiothoracic Surgery, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Surgical Endoscopy</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">14/7(2000-07-01), 682-684</subfield>
   <subfield code="x">0930-2794</subfield>
   <subfield code="q">14:7&lt;682</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">14</subfield>
   <subfield code="o">464</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s004640020077</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s004640020077</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ohtsuka</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Department of Cardiothoracic Surgery, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ohnishi</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">Department of Orthopedics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Nakamura</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Department of Orthopedics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Takamoto</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Department of Cardiothoracic Surgery, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Surgical Endoscopy</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">14/7(2000-07-01), 682-684</subfield>
   <subfield code="x">0930-2794</subfield>
   <subfield code="q">14:7&lt;682</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">14</subfield>
   <subfield code="o">464</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
