<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475780779</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123643.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s004640020067</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s004640020067</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Robotics and telemanipulation technologies for endoscopic surgery</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">A review of the ARTEMIS project</subfield>
   <subfield code="c">[M. O. Schurr, G. Buess, B. Neisius, U. Voges]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Abstract.: In endoscopic surgery, the ability to guide the instrument is significantly decreased compared with open surgery. Rigid laparoscopic instruments offer only four of the six degrees of freedom required for the free handling of objects in space. Robotics technology can be used to restore full mobility of the endoscopic instrument. Therefore, we designed a master-slave manipulator system (ARTEMIS) for laparoscopic surgery as a prototype. The system consists of two robotic arms holding two steerable laparoscopic instruments. These two work units are controlled from a console equipped with two master arms operated by the surgeon. The systems and its components were evaluated experimentally. Laparoscopic manipulations were feasible with the ARTEMIS system. The placement of ligatures and sutures and the handling of catheters were possible in phantom models. The surgical practicability of the system was demonstrated in animal experiments. We conclude that robotic manipulators are feasible for experimental endoscopic surgery. Their clinical application requires further technical development.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag New York Inc., 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Key words: Endoscopic surgery — Instrumentation — Robotics — Telemanipulation — Telesurgery</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schurr</subfield>
   <subfield code="D">M. O.</subfield>
   <subfield code="u">Section for Minimally Invasive Surgery, Eberhard Karls University, Waldhoernlestrasse 22, D-72072 Tübingen, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Buess</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Section for Minimally Invasive Surgery, Eberhard Karls University, Waldhoernlestrasse 22, D-72072 Tübingen, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Neisius</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">Department of Engineering, Karlsruhe Research Center, Karlsruhe, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Voges</subfield>
   <subfield code="D">U.</subfield>
   <subfield code="u">Institute of Applied Informatics, Karlsruhe Research Center, Karlsruhe, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Surgical Endoscopy</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">14/4(2000-04-01), 375-381</subfield>
   <subfield code="x">0930-2794</subfield>
   <subfield code="q">14:4&lt;375</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">14</subfield>
   <subfield code="o">464</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s004640020067</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s004640020067</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schurr</subfield>
   <subfield code="D">M. O.</subfield>
   <subfield code="u">Section for Minimally Invasive Surgery, Eberhard Karls University, Waldhoernlestrasse 22, D-72072 Tübingen, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Buess</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Section for Minimally Invasive Surgery, Eberhard Karls University, Waldhoernlestrasse 22, D-72072 Tübingen, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Neisius</subfield>
   <subfield code="D">B.</subfield>
   <subfield code="u">Department of Engineering, Karlsruhe Research Center, Karlsruhe, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Voges</subfield>
   <subfield code="D">U.</subfield>
   <subfield code="u">Institute of Applied Informatics, Karlsruhe Research Center, Karlsruhe, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Surgical Endoscopy</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">14/4(2000-04-01), 375-381</subfield>
   <subfield code="x">0930-2794</subfield>
   <subfield code="q">14:4&lt;375</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">14</subfield>
   <subfield code="o">464</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
