<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475789652</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123708.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1023/A:1019164611304</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1023/A:1019164611304</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Assigning spare capacities in mesh survivable networks</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Jean-Luc Lutton, Dritan Nace, Jacques Carlier]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">This paper analyses one key issue of designing reliable networks: assignment of spare capacities in transmission networks. The spare capacities are optimized to facilitate the restoration of single failures. This problem can be formulated as an integer linear program and approximated by its continuous relaxation. This model is based on arc-path formulation especially efficient for dealing with end-to-end rerouting and providing appreciable economies in comparison with local rerouting. The main idea of our method resides in a linear programming decomposition, which permits us to solve problems for medium and large networks. Our approach could be applicable to both STM and ATM-based networks. This method was tested successfully on medium and large DCS-meshed networks and some numerical examples are given to illustrate its performances in terms of CPU time and ratio of optimality.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Kluwer Academic Publishers, 2000</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lutton</subfield>
   <subfield code="D">Jean-Luc</subfield>
   <subfield code="u">France Télécom, CNET/DAC/OAT, 38-40 rue du Général-Leclerc, 92794 Issy Moulineaux Cedex 9, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Nace</subfield>
   <subfield code="D">Dritan</subfield>
   <subfield code="u">Centre de Recherches, HEUDIASYC Laboratory, Université de Technologie de Compiègne, UMR CNRS 6599, BP 20 529, 60205 Compiègne Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Carlier</subfield>
   <subfield code="D">Jacques</subfield>
   <subfield code="u">Centre de Recherches, HEUDIASYC Laboratory, Université de Technologie de Compiègne, UMR CNRS 6599, BP 20 529, 60205 Compiègne Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Telecommunication Systems</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">13/2-4(2000-07-01), 441-451</subfield>
   <subfield code="x">1018-4864</subfield>
   <subfield code="q">13:2-4&lt;441</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">13</subfield>
   <subfield code="o">11235</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1023/A:1019164611304</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1023/A:1019164611304</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lutton</subfield>
   <subfield code="D">Jean-Luc</subfield>
   <subfield code="u">France Télécom, CNET/DAC/OAT, 38-40 rue du Général-Leclerc, 92794 Issy Moulineaux Cedex 9, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Nace</subfield>
   <subfield code="D">Dritan</subfield>
   <subfield code="u">Centre de Recherches, HEUDIASYC Laboratory, Université de Technologie de Compiègne, UMR CNRS 6599, BP 20 529, 60205 Compiègne Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Carlier</subfield>
   <subfield code="D">Jacques</subfield>
   <subfield code="u">Centre de Recherches, HEUDIASYC Laboratory, Université de Technologie de Compiègne, UMR CNRS 6599, BP 20 529, 60205 Compiègne Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Telecommunication Systems</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">13/2-4(2000-07-01), 441-451</subfield>
   <subfield code="x">1018-4864</subfield>
   <subfield code="q">13:2-4&lt;441</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">13</subfield>
   <subfield code="o">11235</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
